HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
Attempt to update the PD PDT with OLA Cell failed. Probable Cause: Unable to add
OLA cell's PDT to the partition PDT. Error accessing PDH space. Check fabric
connection between OLA cell and core cell. Recommended Action: Gather IPMI event
logs and contact HP Support. WBEM EventID: 6959. WBEM ProviderName:
FPL_IndicationProviderError8646
Attempt to update the cell map to include the OLA Cell failed. Probable Cause:
Unable to write registers on the CC. Check cell board and system fabric.
Recommended Action: Collect IPMI events and contact HP Support. WBEM EventID:
6960. WBEM ProviderName: FPL_IndicationProviderWarning8647
Fabric Discovery could not initialize the local cell's XBC link. Probable Cause: CC to
XBC link init failure. Recommended Action: check CC, XBC, reset cell, reset backplane
WBEM EventID: 756. WBEM ProviderName: FPL_IndicationProviderError8648
Internal firmware programming error. Probable Cause: Report the IP to the firmware
team. Reset the system. This cannot be worked around in the field. WBEM EventID:
760. WBEM ProviderName: FPL_IndicationProviderError8652
Error writing the XIN init disable register. Probable Cause: Check XBC, CC, backplane
WBEM EventID: 771. WBEM ProviderName: FPL_IndicationProviderError8676
Error reading the XIN init state register. Probable Cause: Check XBC, CC, backplane
WBEM EventID: 772. WBEM ProviderName: FPL_IndicationProviderError8677
intermittent failure while retrying the CC to XBC link init. Probable Cause: contact
your HP service representative WBEM EventID: 773. WBEM ProviderName:
FPL_IndicationProviderError8679
Initialization of a PCI node in the firmware device tree failed. Probable Cause: The
PCI component could not create a device tree node. Recommended Action: This is
an internal system firmware error. Update system firmware or contact a system
firmware representative. WBEM EventID: 774. WBEM ProviderName:
FPL_IndicationProviderWarning8690
An error was encountered while scanning the PCI bus. Probable Cause: The PCI
component experienced an internal system firmware error while scanning the PCI
bus. Recommended Action: This is an internal system firmware error. Update system
firmware or contact a system firmware representative. WBEM EventID: 775. WBEM
ProviderName: FPL_IndicationProviderError8691
An error was encountered initializing the PCI bridge. Probable Cause: The PCI
component could not initialize a P2P bridge registers, probably due to faulty
hardware. Recommended Action: Reseat or replace the PCI bridge card. WBEM
EventID: 776. WBEM ProviderName: FPL_IndicationProviderWarning8692
An error was encountered initializing the PCI IO map. Probable Cause: The PCI
component had insufficient IO port space resources to support the installed PCI
cards. Recommended Action: Remove one or more PCI cards to reduce resource
requirements; check for faulty cards that are requesting more resources than they
need. WBEM EventID: 777. WBEM ProviderName: FPL_IndicationProviderWarning8693
An error was encountered creating the PCI MMIO map. Probable Cause: The PCI
component had insufficient MMIO space to support the installed cards. Recommended
Action: Remove one or more PCI cards to reduce the MMIO requirements; check for
a PCI card requesting more MMIO resources than it needs. WBEM EventID: 778.
WBEM ProviderName: FPL_IndicationProviderWarning8694
There was an error initializing the SBA node. Probable Cause: An error was while
initializing the SBA firmware structures Recommended Action: Correct any previous
errors Invalidate NVM and reset replace the cell board WBEM EventID: 779. WBEM
ProviderName: FPL_IndicationProviderError8709
There was an error discovering the SBA. Probable Cause: An error was discovered
with the SBA during discovery Recommended Action: Correct any previous errors
Replace the I/O backplane WBEM EventID: 780. WBEM ProviderName:
FPL_IndicationProviderError8710
52 WBEM Provider Event Tables