HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
Firmware was unable to find a suitable block of main memory to relocate ROM.
Probable Cause: Probably caused by lots of PDT entries, or no main memory present.
WBEM EventID: 1036. WBEM ProviderName: FPL_IndicationProviderError8747
Cell started OLA but is not configured in the complex profile of the partition. Probable
Cause: Cell was issued an OLA command without first updating the complex profile
to reflect its slot as configured in the partition. Recommended Action: Update the
complex profile to include the new cell. WBEM EventID: 6955. WBEM ProviderName:
FPL_IndicationProviderWarning8752
The Options service received an NVRAM allocation error. Probable Cause: Invalidate
NVRAM and reset. WBEM EventID: 808. WBEM ProviderName:
FPL_IndicationProviderError8756
failure on OLA cell during attempt to synch its real-time clock. Probable Cause:
Couldn't communicate with OLA cell. Recommended Action: Collect IPMI events
and contact HP Support. WBEM EventID: 6956. WBEM ProviderName:
FPL_IndicationProviderWarning8757
SAL errlog access timeout. Probable Cause: Firmware is taking too long to process
requests. WBEM EventID: 810. WBEM ProviderName: FPL_IndicationProviderWarning8758
The Dillon IPR is not cleared after a MAX_RD_CLR_IPR_TRIES on a cell. Probable
Cause: The PDH FPGA IPR is not cleared after a MAX_RD_CLR_IPR_TRIES on a
cell. Recommended Action: Contact HP Support personnel to troubleshoot the
problem. WBEM EventID: 2442. WBEM ProviderName: FPL_IndicationProviderWarning8761
Indicated the Dillon IPR is not cleared after a number of PDC attempts. Probable
Cause: PDH FPGA IPR is not cleared after a number of PDC attempts. Recommended
Action: Contact HP Support personnel to troubleshoot the problem. WBEM EventID:
1759. WBEM ProviderName: FPL_IndicationProviderWarning8762
failed accessing the core cell RTC while synchronizing the OLA cell's RTC. Probable
Cause: Core cell data could not be accessed/fabric connections went bad
Recommended Action: Collect IPMI events and contact HP Support. WBEM EventID:
6957. WBEM ProviderName: FPL_IndicationProviderError8763
The echelon given in the data field is not fully populated. Probable Cause: the specified
echelon is not fully populated and is not usable Recommended Action: add or replace
dimms in the specified echelon WBEM EventID: 816. WBEM ProviderName:
FPL_IndicationProviderWarning8768
Attempted to read the port state from an illegal port number. Probable Cause: An
invalid port number has been provided. The port number will be converted to an
internal port and processing should continue. Recommended Action: Contact HP
Support personnel to analyze the fabric. WBEM EventID: 817. WBEM ProviderName:
FPL_IndicationProviderWarning8771
Attempted to write the port state for an illegal port. Probable Cause: An invalid port
number has been provided. The port number will be converted to an internal port
and processing should continue. Recommended Action: Contact HP Support personnel
to analyze the fabric. WBEM EventID: 818. WBEM ProviderName:
FPL_IndicationProviderWarning8772
The main backplane is reporting the LPM status as fault. Probable Cause: Many
possible causes, repair / replace the appropriate part. WBEM EventID: 1760. WBEM
ProviderName: FPL_IndicationProviderWarning8784
The IO backplane is reporting a LPM status as fault. Probable Cause: Service / replace
the appropriate part of, or the entire backplane. WBEM EventID: 1762. WBEM
ProviderName: FPL_IndicationProviderWarning8787
System firmware was unable to default the complex profile. Probable Cause: Needed
information could not be obtained. Reset the MP. WBEM EventID: 822. WBEM
ProviderName: FPL_IndicationProviderError8797
54 WBEM Provider Event Tables