Unexpected fabric firmware error. Probable Cause: An unanticipated error occurred.
Contact HP Support personnel to analyze the IPMI FPL log. WBEM EventID: 884.
WBEM ProviderName: FPL_IndicationProviderWarning8976
The CPU is performance or functionally restricted. Probable Cause: A CPU is broken.
Replace it. WBEM EventID: 885. WBEM ProviderName: FPL_IndicationProviderWarning8979
The RTC was found to be invalid and has been cleared. Probable Cause: The RTC
was invalid Recommended Action: No action is required. The problem has been
corrected by SFW. WBEM EventID: 886. WBEM ProviderName:
FPL_IndicationProviderWarning8981
Status indicates that the Late Self Tests did not actually run. Probable Cause: This
could be caused by an incompatibity problem between PAL and the CPUs. Check
that PAL supports all the CPUs installed on the system. WBEM EventID: 887. WBEM
ProviderName: FPL_IndicationProviderWarning8982
A fabric walk failed while updating the cell state. Probable Cause: Look for adjacent
chassis codes to determine the cause of FabricWalk failure. Check the backplane and
fabric connectivity. Contact the HP Support Personnel for further troubleshooting.
WBEM EventID: 888. WBEM ProviderName: FPL_IndicationProviderError8983
Could not reset the cell due to failure updating cell state. Probable Cause: Most likely
a failure on the fabric or on the CC. Fabric failures should produce additional chassis
codes. If no additional chassis codes indicate the cause of the failure, then contact
the HP Support Personnel for further troubleshooting. WBEM EventID: 889. WBEM
ProviderName: FPL_IndicationProviderError8984
Table #2 Event ID numbers 9,000 through 12,627
Event DescriptionEvent SeverityEvent ID
DRAM failure on DIMM XX, deallocate rank. Probable Cause: SFW detected a failing
DIMM Recommended Action: Replace the DIMM flagged by SFW WBEM EventID:
890. WBEM ProviderName: FPL_IndicationProviderWarning9000
System Clocks are not valid. Probable Cause: The Cell board has a problem. Either
the Real Time Clock is not working properly or the system is not being clocked at
the value it thinks it is. WBEM EventID: 891. WBEM ProviderName:
FPL_IndicationProviderError9019
Cell Online Addition failed due to fabric access error. Probable Cause: Fabric Access
Failure, Recommended Action: Check CC to CC link. Look for additional failure
chassis codes to provide more detail. WBEM EventID: 892. WBEM ProviderName:
FPL_IndicationProviderError9020
Fabric found a bad XBC port on a reboot. Attempting to route around it. Probable
Cause: link errors. Recommended Action: Run DC Connectivity test. Check flex
cables, XBCs, and CCs. WBEM EventID: 893. WBEM ProviderName:
FPL_IndicationProviderError9021
Could not access an internal firmware table while rerouting XBC port. Probable
Cause: Firmware Error. Recommended Action: Capture chassis codes and contact
HP Support. WBEM EventID: 894. WBEM ProviderName: FPL_IndicationProviderWarning9022
Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause:
Cell hardware problem like PDH memory itself, the coherency controller, the
executing CPU or interaction between any of these cell components. Recommended
Action: Contact HP Support to troubleshoot the cell and either fix it or replace it.
WBEM EventID: 895. WBEM ProviderName: FPL_IndicationProviderWarning9038
Cell/Partition to be reset because PDC couldn't read PDH memory. Probable Cause:
Cell hardware problem like PDH memory itself, the CC chip, the executing CPU or
interaction between any of these cell components. Recommended Action: Troubleshoot
the cell and either fix it or replace it. WBEM EventID: 896. WBEM ProviderName:
FPL_IndicationProviderWarning9039