Event DescriptionEvent SeverityEvent ID
Error clearing the init packet received bit in the XIN error mask. Probable Cause: CC
access failure. Recommended Action: PDC Reviewed alert level for SR - 9/6/03 CC.
WBEM EventID: 938. WBEM ProviderName: FPL_IndicationProviderWarning9432
Failed to read the XBC's Port Status register. Probable Cause: fabric access failure
Recommended Action: Check XBC, Check CC, Check backplane WBEM EventID:
939. WBEM ProviderName: FPL_IndicationProviderWarning9433
PDHC has detected the PDH battery low warning. Probable Cause: PDH battery
power is low. Recommended Action: Replaced the PDH battery. WBEM EventID:
1037. WBEM ProviderName: FPL_IndicationProviderWarning9438
FW will not handoff to the OS_MCA handler for this MCA event. Probable Cause:
The error logs should be retrieved from the EFI shell prompt. WBEM EventID: 941.
WBEM ProviderName: FPL_IndicationProviderError9440
Resetting the partition because couldn't access PDH memory. Probable Cause: CPU
is on unreachable cell Defective CPU Recommended Action: Contact HP Support
personnel to troubleshoot cell board Investigate for fabric problem WBEM EventID:
1766. WBEM ProviderName: FPL_IndicationProviderError9441
Resetting the partition because a processor was not in expected state. Probable Cause:
Software has not correctly returned all CPUs to sleep state Recommended Action:
Reset would clear this issue WBEM EventID: 1767. WBEM ProviderName:
FPL_IndicationProviderError9442
Halting the cell because a cell couldn't access its own PDH memory. Probable Cause:
Hardware problem with the CPU or cell board. Recommended Action: Contact HP
Support to confirm the CPUs and cell board are functioning properly. WBEM EventID:
1768. WBEM ProviderName: FPL_IndicationProviderWarning9445
The NVRAM block table maintained by System Firmware is corrupt. Probable Cause:
The NVRAM-based descriptor for System Firmware NVRAM blocks is corrupt.
WBEM EventID: 942. WBEM ProviderName: FPL_IndicationProviderError9448
Resetting cell because processor couldn't access it's own PDH memory. Probable
Cause: PDC bug. Recommended Action: Contact HP Support to check for PDC
upgrade. WBEM EventID: 1769. WBEM ProviderName: FPL_IndicationProviderWarning9450
All CPUs were deconfigured and have now been reconfigured. Probable Cause: User
test operational error. Recommended Action: Reboot system and update CPU
configuration as desired. WBEM EventID: 943. WBEM ProviderName:
FPL_IndicationProviderWarning9460
A failure has occurred trying to get the number of CPU cores per module. Probable
Cause: Hardware failure with CPU, CC or cell board. Recommended Action: Contact
HP Support to confirm the CPUs, CC, and cell board are functioning properly. Update
PDC if a version is available to fix this problem. WBEM EventID: 944. WBEM
ProviderName: FPL_IndicationProviderWarning9461
Couldn't read the topology from the XBC register. Probable Cause: Fabric Access
Error Recommended Action: Contact HP Support personnel to check the XBC,
Backplane, CC WBEM EventID: 945. WBEM ProviderName: FPL_IndicationProviderWarning9465
Attempt to update Cell Static Routing has failed. Probable Cause: Fabric Access Error
Recommended Action: Contact HP Support personnel to analyze the fabric. WBEM
EventID: 1776. WBEM ProviderName: FPL_IndicationProviderError9466
Failed to read the XBC CSR that contains the number of failed links. Probable Cause:
Fabric Access Failure Recommended Action: Contact HP Support personnel to analyze
the fabric. WBEM EventID: 947. WBEM ProviderName: FPL_IndicationProviderWarning9468
Failed to read the XBC CSR that contains the number of failed links. Probable Cause:
Fabric Access Failure Recommended Action: Contact HP Support personnel to check
XBC, Backplane, CC, look for additional chassis codes to describe the problem. WBEM
EventID: 948. WBEM ProviderName: FPL_IndicationProviderWarning9469
Platform Events 63