HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
The system firmware had an error with the structured error handling mechanism.
Probable Cause: Either there is an error in the system firmware or the system firmware
has exhausted all resources. Recommended Action: Invalidate NVM or check for
newer version of system firmware. WBEM EventID: 963. WBEM ProviderName:
FPL_IndicationProviderError9486
Not enough malloc resources for I/O structure error handling. Probable Cause: Either
invalidate NVM or check for a new version of system firmware. WBEM EventID:
964. WBEM ProviderName: FPL_IndicationProviderError9487
Unable to create entry for I/O structure error handling. Probable Cause: This is a
system firmware error, either invalidate NVM or check for a newer version of system
firmware. WBEM EventID: 965. WBEM ProviderName: FPL_IndicationProviderError9488
Unable to bind services for I/O structure exception handling. Probable Cause: This
is a system firmware error. Either reset NVM or check for a newer version of system
firmware. WBEM EventID: 966. WBEM ProviderName: FPL_IndicationProviderError9489
Error initializing the I/O structure exception handling services. Probable Cause: This
is a system firmware error. Either reset NVM or check for a newer version of system
firmware. WBEM EventID: 967. WBEM ProviderName: FPL_IndicationProviderError9490
Error initializing structured I/O exception data structures. Probable Cause: This is a
system firmware error, there is a conflict with system resources. Either reset NVM
or check for a newer version of system firmware. WBEM EventID: 968. WBEM
ProviderName: FPL_IndicationProviderError9491
The I/O exception context has an error. Probable Cause: This is a system firmware
error. Reset the system, invalidate NVM and reset the system, or check for a newer
version of the system firmware. WBEM EventID: 969. WBEM ProviderName:
FPL_IndicationProviderError9492
Error creating the internal data and services for the SBA. Probable Cause: This is a
system firmware error. Reset the system; invalidate NVM and reset the system; or
check for a newer version of system firmware. WBEM EventID: 970. WBEM
ProviderName: FPL_IndicationProviderError9493
Error attaching the services to the SBA internal data structures. Probable Cause: This
is a system firmware error. Reset the partition; invalidate NVM on the reporting cell
and reset the system; or check for a newer version of system firmware. WBEM
EventID: 971. WBEM ProviderName: FPL_IndicationProviderError9494
Error initializing the internal SBA data and services. Probable Cause: This is a system
firmware error. Reset the partition; invalidate NVM on the reporting cell and reset
the partition; or check for newer system firmware. WBEM EventID: 972. WBEM
ProviderName: FPL_IndicationProviderError9495
The SBA type is unknown to the system firmware. Probable Cause: This is either a
system firmware error, or the wrong I/O is connected to the system. Validate the
system recipe both firmware and hardware. WBEM EventID: 973. WBEM
ProviderName: FPL_IndicationProviderError9496
An embedded I/O device is missing. Probable Cause: Replaces the I/O card specified
by the physical location. WBEM EventID: 974. WBEM ProviderName:
FPL_IndicationProviderWarning9497
Fabric link route around failed because the route around port was bad. Probable
Cause: 2 or more XBC links are not routable. Recommended Action: Contact HP
Support personnel to check the XBC, Flex Cables, Backplane, CCs, etc WBEM EventID:
975. WBEM ProviderName: FPL_IndicationProviderWarning9498
Predictive Failure in Memory. Probable Cause: You will receive this message if the
memory system is observing a lot of corrected ECC errors from a DIMM. The specified
DIMM may need to be serviced. Recommended Action: Contact your HP support
representative to check the affected hardware. WBEM EventID: 1805. WBEM
ProviderName: FPL_IndicationProviderWarning9652
Platform Events 65