HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
Firmware unable to relocate VGA BIOS. Probable Cause: Most likely there is a
permanent memory error in the VGA BIOS region (physical address 0xc0000 - 0xdffff).
Recommended Action: Replace the DIMM causing the permanent memory error in
the VGA BIOS region. The PDT reports which DIMM is causing errors in the physical
address range 0xc0000 - 0xdffff. WBEM EventID: 986. WBEM ProviderName:
FPL_IndicationProviderWarning9682
The Compatibility Matrix stored in NVRAM has a checksum error. Probable Cause:
NVRAM has become corrupt. Restore from a backup. WBEM EventID: 987. WBEM
ProviderName: FPL_IndicationProviderError9685
PDC failed its attempt to get default RDR values. Probable Cause: Hardware problem
with the CPU. Recommended Action: Contact HP Support to confirm the CPU is
functioning properly. WBEM EventID: 1811. WBEM ProviderName:
FPL_IndicationProviderError9695
PDC could not read current RDR values of the executing CPU. Probable Cause:
Hardware problem with the CPU. Recommended Action: Contact HP Support to
confirm the CPU is functioning properly. WBEM EventID: 1812. WBEM
ProviderName: FPL_IndicationProviderError9696
PDC failed reading a specific value from its own copy of the RDRs. Probable Cause:
problem on cell wherein PDC could not properly access memory Recommended
Action: Contact HP support to troubleshoot cell board. Probable Cause: a
non-existent/non-accessible register was specified by software. Recommended Action:
Contact HP support for possible PDC upgrade WBEM EventID: 1813. WBEM
ProviderName: FPL_IndicationProviderError9697
PDC failed reading a specific value from its own copy of the RDRs. Probable Cause:
problem on cell wherein PDC could not properly access memory Recommended
Action: Contact HP support to troubleshoot cell board WBEM EventID: 1814. WBEM
ProviderName: FPL_IndicationProviderError9698
PDC failed attempting to update ZLCO and PREFETCH RDR settings. Probable
Cause: Could not update CPU settings Recommended Action: Contact HP support
to troubleshoot cell board and CPU. WBEM EventID: 1815. WBEM ProviderName:
FPL_IndicationProviderError9700
PDC failed to read the HV Flag in the Partition Configuration Data. Probable Cause:
An error occurred which prevented the complex profiles from being distributed
properly. Recommended Action: Create and distribute a new complex profile using
ParMgr on a functional partition in the complex. Restore the last complex profile
using the 'CC' command from the MP, then use ParMgr to create a new complex
profile. Generate a genesis complex profile using the 'CC' command from the MP,
then use ParMgr to create a new complex profile. WBEM EventID: 1816. WBEM
ProviderName: FPL_IndicationProviderError9701
Failed to get the configured set from the Complex Profiles A and C. Probable Cause:
A hardware problem exists with MP or PDHC hardware. Recommended Action:
Contact HP Support to confirm the MP and PDHC are functioning properly. WBEM
EventID: 993. WBEM ProviderName: FPL_IndicationProviderWarning9706
No possible core cells were found in the configured set. Probable Cause: most likely
a configuration problem, Recommended Action: check to ensure a valid core cell is
configured to be in the partition. WBEM EventID: 994. WBEM ProviderName:
FPL_IndicationProviderWarning9707
Could not find a viable core cell in the partition. Probable Cause: Configuration error,
fabric failure; the intended core cell failed during boot. Recommended Action: check
partition configuration, check for failed cells. WBEM EventID: 995. WBEM
ProviderName: FPL_IndicationProviderWarning9708
Could not find a viable core cell in the partition. Probable Cause: Configuration error,
Mainbackplane failure, The intended core cell failed during boot. Recommended
Action: Check partition configuration, Check for failed cells, as indicated by high-alert
level IPMI events earlier in the boot. WBEM EventID: 996. WBEM ProviderName:
FPL_IndicationProviderWarning9709
Platform Events 67