HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
Right ejector latch is open. Probable Cause: The right ejector latch is open.
Recommended Action: Close the right ejector latch on the specified cell. WBEM
EventID: 2412. WBEM ProviderName: FPL_IndicationProviderWarning10061
The optical emitters on the cell latch sensors are not functioning. Probable Cause:
There is a hardware failure. Recommended Action: The cell board must be repaired
or replaced. WBEM EventID: 2411. WBEM ProviderName: FPL_IndicationProviderWarning10062
The vrm on the specified cell is reporting a voltage fault. Probable Cause: The specified
vrm is reporting a fault. Recommended Action: Replace the specified VRM. The
datafield contains the physical location. Byte 16 is the cabinet, byte 13 is the cell slot,
and byte 11 is the vrm slot. The vrm slot in byte 11 matches the vrm number
silkscreened on the cell board. WBEM EventID: 2485. WBEM ProviderName:
FPL_IndicationProviderWarning10063
The vrm on the specified cell is reporting a temperature fault. WBEM EventID: 2486.
WBEM ProviderName: FPL_IndicationProviderWarning10064
The rail on a cell is reporting a fault. WBEM EventID: 2487. WBEM ProviderName:
FPL_IndicationProviderWarning10065
A I/O backplane vrm is reporting a voltage fault. WBEM EventID: 2488. WBEM
ProviderName: FPL_IndicationProviderWarning10068
A I/O backplane power brick is reporting a voltage fault. WBEM EventID: 2489.
WBEM ProviderName: FPL_IndicationProviderWarning10069
A I/O backplane vrm is reporting a temperature fault. WBEM EventID: 2490. WBEM
ProviderName: FPL_IndicationProviderWarning10070
A I/O backplane power brick is reporting a temperature fault. WBEM EventID: 2491.
WBEM ProviderName: FPL_IndicationProviderWarning10071
A I/O backplane vrm rail is reporting a fault. WBEM EventID: 2492. WBEM
ProviderName: FPL_IndicationProviderWarning10072
A I/O backplane power brick is reporting a rail fault. WBEM EventID: 2493. WBEM
ProviderName: FPL_IndicationProviderWarning10073
The specified system backplane vrm is reporting a module voltage fault. WBEM
EventID: 2495. WBEM ProviderName: FPL_IndicationProviderWarning10103
The specified system backplane vrm is reporting a temperature fault. WBEM EventID:
2496. WBEM ProviderName: FPL_IndicationProviderWarning10104
The specified system backplane rail is reporting a fault WBEM EventID: 2497. WBEM
ProviderName: FPL_IndicationProviderWarning10105
Master MP failure. Slave MP has taken control WBEM EventID: 2484. WBEM
ProviderName: FPL_IndicationProviderWarning10115
The NVRAM service was unable to satisfy an NVRAM allocation request. Probable
Cause: NVRAM is full. This is extremely unlikely. Recommended Action: Clear
NVRAM and reset. WBEM EventID: 2499. WBEM ProviderName:
FPL_IndicationProviderError10116
The RTC not updating its internal time registers. Probable Cause: Bad RTC chip on
the PDH daughtercard. Recommended Action: Replace PDH daughtercard WBEM
EventID: 2512. WBEM ProviderName: FPL_IndicationProviderError10132
Uncorrectable PAA fault on MX2. Probable Cause: An uncorrectable PAA fault has
occurred on the MX2 module and PAA firmware has halted. Recommended Action:
Contact your HP support personnel. WBEM EventID: 2740. WBEM ProviderName:
FPL_IndicationProviderWarning10159
72 WBEM Provider Event Tables