HP Insight Manager WBEM Provider Events Reference
Event DescriptionEvent SeverityEvent ID
System Firmware was unable to access the configured set stored in the complex
profile. Probable Cause: SFW was unable to access the configured set stored in the
complex profile. Recommended Action: Collect IPMI events and contact your HP
Support Representative. WBEM EventID: 6874. WBEM ProviderName:
FPL_IndicationProviderWarning10481
System Firmware detected an error during Fabric Init. Probable Cause: Error detected
by SFW during Fabric Init. Recommended Action: Collect IMPI events and contact
your HP Support Representative for assistance. WBEM EventID: 6869. WBEM
ProviderName: FPL_IndicationProviderWarning10482
System Firmware detected a failure during Fabric Init. Probable Cause: Failure
detected by SFW during Fabric Init. Recommended Action: Collect IPMI events and
contact your HP Support Representative for assistance. WBEM EventID: 6870. WBEM
ProviderName: FPL_IndicationProviderWarning10483
System Firmware detected an error during Fabric Optimize. Probable Cause: Error
detected by SFW during Fabric Optimize. Recommended Action: Collect IMPI events
and contact your HP Support Representative for assistance. WBEM EventID: 6871.
WBEM ProviderName: FPL_IndicationProviderWarning10487
Input power to the specified UPS has failed. WBEM EventID: 2963. WBEM
ProviderName: FPL_IndicationProviderWarning10489
Input power to the specified UPS has been restored. WBEM EventID: 2964. WBEM
ProviderName: FPL_IndicationProviderWarning10490
UPS power exhausted. The system is being powered down. WBEM EventID: 2970.
WBEM ProviderName: FPL_IndicationProviderError10495
During Machine Check handling, SAL failed to rendezvous all the processors.
Probable Cause: System firmware cannot roundup the processors during the machine
check handler. Recommended Action: Check for faulty processor, possibly the one(s)
that failed to rendezvous. Contact your HP representative for support. WBEM
EventID: 6855. WBEM ProviderName: FPL_IndicationProviderWarning10509
SAL failed to clear the CEC logs during Machine check handling. Probable Cause:
System firmware failed to clear the CEC logs. Recommended Action: Check for
multiple errors or bad CEC. Contact your HP representative for support. WBEM
EventID: 6856. WBEM ProviderName: FPL_IndicationProviderWarning10510
System FW was unable to access the XBC semaphore. Probable Cause: System FW
was unable to access the XBC semaphore. Recommended Action: Collect IPMI events,
look for additional errors events, and contact HP support for assistance. WBEM
EventID: 6868. WBEM ProviderName: FPL_IndicationProviderWarning10516
System Firmware detected an error while trying to release the XBC Global Semaphore.
Probable Cause: Error detected by SFW while trying to release the XBC Global
Semaphore. Recommended Action: Collect IPMI events and contact your HP Support
Representative. WBEM EventID: 6872. WBEM ProviderName: FPL_IndicationProviderWarning10518
System Firmware detected an Error while checking the owner of the XBC Global
Semaphore. Probable Cause: Error detected by SFW while checking the owner of the
XBC Global Semaphore. Recommended Action: Collect IMPI events and contact your
HP Support Representative. WBEM EventID: 6873. WBEM ProviderName:
FPL_IndicationProviderWarning10519
An error occurred while forming the XBC semaphore address. Probable Cause:
Couldn't determine the proper address of the XBC semaphore Recommended Action:
Save IPMI event codes, contact HP Support Representative to analyze the fabric
WBEM EventID: 4850. WBEM ProviderName: FPL_IndicationProviderWarning10520
Error reading the XBC Global Semaphore. Probable Cause: Couldn't read the XBC
semaphore Recommended Action: Look for additional IPMI event logs, contact your
HP support representative to analyze the fabric WBEM EventID: 4851. WBEM
ProviderName: FPL_IndicationProviderWarning10521
78 WBEM Provider Event Tables