HP Insight Manager WBEM Provider Events Reference

Event DescriptionEvent SeverityEvent ID
This is an internal SW error. See Cause/Action. Probable Cause: A CPU has tried to
acquired the same semaphore twice which resulted in a deadlock. This is an internal
SFW error and is not recoverable. Recommended Action: Collect the entire FPL, SEL,
console logs and forward them to the SFW team. Also note all activities around the
time of this event. The entire logs must analyzed by the SFW team before further
actions can be taken. The system must be cold reset to resume normal operation
WBEM EventID: 6695. WBEM ProviderName: FPL_IndicationProviderError12195
This is an internal SW error. See Cause/Action. Probable Cause: A CPU has tried to
acquired the same semaphore twice which resulted in a deadlock. This is an internal
SFW error and is not recoverable. Recommended Action: Collect the entire FPL, SEL,
console logs and forward them to the SFW team. Also note all activities around the
time of this event. The entire logs must analyzed by the SFW team before further
actions can be taken. The system must be cold reset to resume normal operation
WBEM EventID: 6696. WBEM ProviderName: FPL_IndicationProviderError12196
The complex profiles between cells in a partition do not match. Data field is unused,
earlier events will give more detail. Probable Cause: The Group A or Group C complex
profiles didn't match on all cells in the partition. Recommended Action: Push out
new complex profiles and reset. WBEM EventID: 6698. WBEM ProviderName:
FPL_IndicationProviderError12199
An I/O device is missing from the Core I/O. Probable Cause: Either an I/O device on
the Core I/O has failed or the wrong card is plugged into the location of the expected
Core I/O. Recommended Action: Replace the specified location with the supported
Core I/O card. WBEM EventID: 6699. WBEM ProviderName: FPL_IndicationProviderWarning12204
fPars PMI handler was unable to Notify a CPU's new owner after a migrate. Probable
Cause: OS has not fully set up GPE enable bits with the FSHWA interface
Recommended Action: Contact HP support. WBEM EventID: 6701. WBEM
ProviderName: FPL_IndicationProviderWarning12207
fPars PMI handler was unable to Notify a CPU's new owner after a migrate. Probable
Cause: OS incorrectly set up the IOSAPIC redirection entry through the FSHWA
interface. Recommended Action: Contact HP support. WBEM EventID: 6702. WBEM
ProviderName: FPL_IndicationProviderWarning12208
The operating system set the watchdog timer to time out if it was not reset within a
specified time. It was not reset and has timed out. The management processor will
now take the action specified when the timer was set. Probable Cause: Operating
system has not reset watchdog timer. Recommended Action: Determine why operating
system did not reset the timer WBEM EventID: 6703. WBEM ProviderName:
FPL_IndicationProviderWarning12210
An OS is shutting down due to an MCA (Machine Check Abort) or INIT. Probable
Cause: An MCA or INIT occurred. Recommended Action: Analyze the dump + logs
for cause. If necessary contact HP Support for assistance. WBEM EventID: 6772.
WBEM ProviderName: FPL_IndicationProviderError12217
An OS is shutting down due to a panic. Probable Cause: An OS has panicked.
Recommended Action: Analyze the dump + logs for cause. If necessary contact HP
Support for assistance. WBEM EventID: 6773. WBEM ProviderName:
FPL_IndicationProviderError12218
An instance of CLU FW has an installed firmware revision that is incompatible with
the system type. Many system operations will fail until this condition is resolved.
Probable Cause: Following an in-the-box system type upgrade, or after a UGUY
board was replaced, the CLU FW may not have been updated to an appropriate
revision for the system type. Recommended Action: Contact your HP Customer
Support Representative to update all firmware entities to revisions that are appropriate
for the system type. WBEM EventID: 6771. WBEM ProviderName:
FPL_IndicationProviderError12222
The online diagnostics have identified a hardware problem. Probable Cause: OS
based diagnostics discovered a hardware problem. Recommended Action: Consult
the OS diagnostics logs for details about the problem. WBEM EventID: 6779. WBEM
ProviderName: FPL_IndicationProviderError12227