HP Integrity rx8620 Server User Service Guide
NOTE: You may need to allow time for some components to complete power on self test
(POST) before a complete status is available.
4. Reboot each nPartition. See Appendix E (page 203).
5. Verify system functionality by using the Online Diagnostic Support Tools Manager (STM)
exerciser.
Removing and Replacing Covers
It is necessary to remove one or more of the covers to access many of the FRUs within the server
chassis.
Figure 6-1 Cover Locations
Removing the Top Cover
To remove the top cover, follow these steps:
1. Connect to ground with a wrist strap. see “Electrostatic Discharge ” (page 106).
2. Loosen the blue retaining screws securing the cover to the chassis.
3. Slide the cover toward the rear of the chassis.
4. Lift the cover up and away from the chassis.
5. Place the cover in a safe location.
108 Removal and Replacement