HP Integrity rx8620 Server User Service Guide
1. Identify the failed fan assembly. Table 6-2 defines the fan LED states.
Table 6-2 Smart Fan Assembly LED Indications
MeaningLED State
Fan is at speed and in sync or not at speed less than 12 seconds.On Green
Fan is not keeping up with speed/sync pulse for greater than 12 seconds.Flash Yellow
Fan failed or stalled, has run slow, or fast for greater than 12 seconds.Red
Fan is not present, or no power is applied to fan, or the fan has failed.Off
2. Loosen the two thumb screws securing the fan to the chassis.
3. Slide the fan from the chassis.
Replacing the Rear Smart Fan Assembly
To replace the rear smart fan assembly, follow these steps:
1. Position the fan assembly in the chassis.
2. Slide the fan into the connector.
3. Tighten the two thumb screws to secure the fan to the chassis.
4. The LED should be GREEN. For a listing of LED definitions, see Table 6-2 (page 117).
Removing and Replacing a Disk Drive
The disk drive is located in the front of the chassis. Internal disk drives are hot-plug components.
Figure 6-12 Disk Drive Location
Removing and Replacing a Disk Drive 117