NOTE: The PDHC state should read Attention LED is off, and the Power Status
should read RDY. If the Power Status reads rdy, then one or both of the extraction levers
are not properly locked. Ensure both cell board extraction levers are locked. Figure 6-19
shows a sample of the output.
Figure 6-19 de Command Output
6. Replace the right side cover. See “Replacing the Side Cover” (page 110).
Cell Break-Fix Upgrade and Downgrade Procedure
This release notice provides information, upgrade and downgrade instructions for the rp7420,
rp8420, rx7620 and an rx8620 system products. These instructions pertain to a break fix scenario
where a replacement cell is added to a currently operating system.
Upgrading Using the FW Command
To upgrade using the FW command, follow these steps: