HP Integrity rx8620 Server User Service Guide

(see Note (1) in this step).
NOTE (1): X.X.X is the version number corresponding to the version of the PDHC firmware
on the other cells.
Example (rp8420 with SEU):
MP:CM> fw
*********************************************************************
***** *****
***** Firmware Update Utility *****
***** *****
***** (C) Copyright 2001 Hewlett-Packard Company *****
***** All Rights Reserved *****
***** *****
***** THIS PROGRAM IS NOT LICENSED TO CUSTOMERS *****
***** *****
***** This program is intended for use by trained HP support *****
***** personnel only. HP shall not be liable for any damages *****
***** resulting from unauthorized use of this program. This *****
***** program is the property of HP. *****
***** *****
***** Version 4.00 *****
***** *****
*********************************************************************
Flash Current
Number Cabinet Name Partition Handle Firmware Version Comments
------ --------- -------- ---------- -------- ------------------ --------
(1) 1 0 MP 0 0 0 5.022 Master
(1) 2 0 MP 1 1 1 5.022 Slave
(3) 3 (2) 8 MP 0 0 32768 5.022 Master
(3) 4 (2) 8 MP 1 1 32769 5.022 Slave
5 0 PDHC 0 0 256 3.012 -
6 0 SFW 0 0 320 21.003 -
7 0 PDHC 1 1 257 3.014 -
8 0 SFW 1 1 321 21.003 -
(3) 9 0 PDHC 2 0 258 3.014 -
(3) 10 0 SFW 2 0 322 21.003 -
(3) 11 0 PDHC 3 1 259 3.014 -
(3) 12 0 SFW 3 1 323 21.003 -
Enter the Entities to be upgraded (Ex: 3,4,10): 5
Enter your user name: anonymous
Enter your user password: ********
Enter the ip address where the firmware can be found: 192.1.1.1
Enter the path where the firmware can be found: /dist/versionX_X
Enter the filename of the firmware image for the PDHC: pdhc_A.X.X.X.bin
Are you sure that you want to continue(Y/N): y
**** Firmware Updating PDHC ****
Firmware updating progress will be reported
NOTE: 1. When a SEU is connected to an rp8420 system, the cabinet id 8 is assigned to the
SEU.
2. These entities will only be seen on the rp8420.
3. X.X.X is the version number corresponding to the version of the PDHC Firmware on the
other cells.
5. Ensure the entity selected was updated successfully. A successful update returns the following
message:
Firmware Update has completed successfully for all entities.
MP:CM>
An unsuccessful update results in an error message. If the FTP connection was successful,
but the update failed, a warning is noted for the entity being updated. For example:
Removing and Replacing a Cell Board 127