HP Integrity rx8620 Server User Service Guide
Flash Current
Number Cabinet Name Partition Handle Firmware Version Comments
------ --------- -------- --------- -------- ------------------ --------
1 0 PDHC 0A 0 256 A.003.034 Current
2 0 PDHC 0B 0 264 A.003.034 Old
3 0 SFW 0A 0 320 21.001 Pri PA
4 0 SFW 0B 0 328 22.002 Sec PA
5 0 PDHC 1A 0 257 A.003.034 Current
6 0 PDHC 1B 0 265 A.003.034 Old
7 0 SFW 1A 0 321 21.001 Pri PA
8 0 SFW 1B 0 329 21.001 Sec PA
Note: You can only duplicate one firmware type at a time.
Enter the Entities to be updated (EX: 7,8) : 4
Enter the source entity for the System firmware image: 7
Are you sure that you want to continue(Y/N): y
**** Updating device SFW 0B ****
Erasing Flash(es). This may take several minutes.
DFW has completed successfully for all entities
Once DFW has completed, verify the following message is returned:
DFW has completed successfully for all entities
CAUTION: DO NOT RESET or AC POWER CYCLE the cell or server unless you have
received confirmation that DFW has completed successfully. Repeat the dfw command
immediately if the firmware failed to complete successfully.
8. Perform steps 11 and 12 from Step 11.
Installing the VRM Cover (AB388-00002) and Door Opener
(AB388-00003)
These two assemblies replace the single CPU cover when installing PA8800 and Dual-Core IPF
processors. The assemblies are included in upgrade kits and will not be available to order
individually. The following is a list of processors that require the new air baffles.
• Intel ® Itanium® 2 CPUs (AB548A and AB439A)
• PA8800 CPUs (AB536A and AB537A)
To install new air baffles, follow these steps:
1. Remove the old CPU cover.
2. Install the VRM Cover (AB388-00002), onto the left side of the cell board. Tighten the screw.
See Figure 6-20.
Installing the VRM Cover (AB388-00002) and Door Opener (AB388-00003) 137