Installation Guide, Sixth Edition - HP Integrity rx8620 Server

Chapter 2
Installation
Cabling and Power Up
89
1. If there is a Server Expansion Unit attached to the server, both the server and the SEU power switch
needs to be pressed. Alternatively, at the MP:CM> prompt, the PE X command can be used to power on the
complex or the PE T command can be used for each cabinet. The following events occur:
Power is applied to the server.
Processor Dependent Code (PDC) starts to run on each cell.
The cell self test executes.
Hardware initializes for the server.
Console communication is established.
2. Once the cell has joined the partition or once boot is blocked (BIB) is displayed at the virtual front panel
(VFP), return to the MP Main Menu by entering Ctrl-B.
3. Enter co to enter console mode.
4. Enter the partition number of the partition to boot.
5. Press
Enter.