Site Preparation Guide, Fourth Edition - HP Integrity rx8620 Server

Chapter 1
System Specifications
Dimensions and Weights
4
Dimensions and Weights
This section provides dimensions and weights of the server and server components.
Table 1-2 provides component weights for calculating the weight of a server not fully configured. Table 1-7 on
page 12 provides an example of how to calculate the weight. Table 1-8 on page 12 is a blank worksheet for
calculating the weight of the server.
Table 1-1 HP Integrity rx8620 Server Dimensions and Weights
Stand-alone Packaged
Height - Inches (centimeters) 29.55 (75.00) 86.50 (219.70)
Width - Inches (centimeters) 17.50 (44.50) 40.00 (101.60)
Depth - Inches (centimeters) 30.00 (76.20) 48.00 (122.00)
Weight - Pounds (kilograms)
368.00
a
(166.92)
a. This weight represents a fully configured server before it is installed in a
rack.
813.00
b
(368.77)
b. The packaged weight represents a server installed in a 2-m rack. The
packaged weight includes a fully configured server in a 2-m rack with a rear
door, rail slide kit, line cord anchor kit, interlock assembly, cable
management arm, 120 lb. ballast kit, and a 60A PDU. The shipping box,
pallet, and container, not included in the packaged weight in Table 1-1, adds
approximately 150.0 lb. to the total system weight when shipped. The size
and number of miscellaneous pallets will be determined by the equipment
ordered by the customer.
Table 1-2 HP Integrity rx8620 Server Component Weights
Quantity Description Weight (lb./kg.)
1 Chassis 131.00 (59.42)
1 System backplane 20.0 (9.07)
1 PCI-X card cage assembly 20.40 (9.25)
2 PCI-X power supply 5.00 (2.27) each
6 Bulk power supply 12.00 (5.44) each
1 Mass storage backplane 1.00 (0.45)
1 - 4 Cell board 27.80 (12.61) each
1 - 4 Hard disk drive 1.60 (0.73) each
1 - 2 Removable media disk drive 2.20 (1.00) each