HP Integrity rx8640, HP 9000 rp8440 Server User Service Guide

Table 25 Front Panel LEDs (continued)
DescriptionStatusLED
Cell power OffGreen (flashing)
Cell power OnGreen (solid)
Cell fault warning. Check for:Amber (flashing)
Cell latches not latched
LPM not ready
Cell VRMs reporting not good or overtemp
Cell fan slow/failed
Cell fault. Check for:Red (solid)
Cell powered Off due to power problem
HPMC/MC event from cell
Timeout or user requests locator OffOffLocate
User requests locator On and specifies (1–72) hour Off timeout
(Default timeout is 24 hours)
Blue (flashing)
Bulk Power Supply LEDs
There is a single, three-color LED located on each bulk power supply.
Figure 51 BPS LED Location
BPS LED
Location
Table 26 BPS LEDs
DescriptionLED Indication
BPS in standby state and no faults or warningsBlink Green
BPS in run state (48 V output enabled) and no faults or warningsGreen
114 Server Troubleshooting