HP Integrity rx8640, HP 9000 rp8440 Server User Service Guide
Table 38 BPS LED Definitions (continued)
DescriptionLED State
BPS state may be unknown, nonrecoverable faults are present.Blink RED
This LED state is not used.Red
BPS fault or failure (unless AC power is not connected to server).Off
3. Depress the release latch on the upper front center portion of the BPS (Figure 93).
4. Slide the BPS forward using the handle to remove it from the chassis.
Figure 93 BPS Detail
Release Latch
Replacing the BPS
1. Grip the handle with one hand while supporting the rear of the BPS in the other hand.
NOTE: The BPS easily slides into the chassis; apply a slow, firm pressure to properly seat
the connection.
2. Slide the power supply into the slot until it is fully seated.
When seated, the release latch will click and lock into place.
3. Note status of the BPS LED. The LED should be green.
NOTE: When a BPS fails and is replaced on line, the PS command will sometimes display
the cached status data of the BPS. Use the CM>DE command to verify the actual state of the
BPS.
4. Replace the front bezel.
Removing and Replacing a Bulk Power Supply (BPS) 157