Installation Guide, Third Edition - HP Integrity rx8640 SEU

7. Roll the lifter and SEU away from the pallet. Do not raise the SEU any higher than necessary
when moving it over to the rack.
Figure 2-7 Lifting the SEU into Position for Rack Installation
Installing the Cable Management Arm
After the SEU is installed in the rack, the cable management arm (CMA) must be installed on
the rear of the SEU. Follow the instructions for installing the CMA in the installation guide, hp
J1530B, rack integration kit (lower case intended). The CMA is attached to the rack using screws
supplied in the kit. The other end of the CMA is attached to the SEU using custom nuts supplied
in the kit. The installation guide is on the Web at http://www.hp.com/racksolutions
Installing the Rack Interlock Device Assembly
Once the CMA is installed on the rear of the SEU then the interlock device assembly must be
installed. Follow the instructions for installing the interlock device assembly in the installation
guide, hp J1530B, rack integration kit (lower case intended). The installation guide is on the Web
at http://www.hp.com/racksolutions
Installing SEU without a Mechanical Lift
Use this procedure only if an HP approved lift is not available.
This procedure should only be performed by two qualified HP Service technicians utilizing
proper lifting techniques and procedures.
30 Installing the Server Expansion Unit