User Service Guide, Fifth Edition - HP Integrity rx8640 SEU
NOTE: Fans driven to a high RPM in dense air cannot maintain expected RPM and will be
considered bad by the MP leading to a “False Fan Failure” condition.
PCI-X Slot Boot Paths
Table 1-3 and Table 1-3 list the mapping of PCI-X slots to ropes and boot paths. Pathing will have
to be modified for PCI cards that have different devices and functions. The cell column refers to
the cell board installed in the server in cell slot 2 and in cell slot 3
Table 1-2 Cell 2 PCI Slot Boot Paths
PathRopesPCI SlotCell
2/0/8/1/08/912
2/0/10/1/010/1122
2/0/12/1/012/1332
2/0/14/1/014/1542
2/0/6/1/06/752
2/0/4/1/04/562
2/0/2/1/02/372
2/0/1/1/0182
Table 1-3 Cell 3 PCI Slot Boot Paths
PathRopesPCI SlotCell
3/0/8/1/08/913
3/0/10/1/010/1123
3/0/12/1/012/1333
3/0/14/1/014/1543
3/0/6/1/06/753
3/0/4/1/04/563
3/0/2/1/02/373
3/0/1/1/0183
PCI-X/PCIe I/O Backplane
The 16-slot (8 PCI and PCI-X; 8 PCI-Express) mixed PCI-X/PCI Express I/O backplane is heavily
leveraged from the PCI-X backplane design. Only the differences will be described here. See
“PCI-X Backplane” (page 18) for common content between the two boards.
NOTE: Troubleshooting instructions and card cage information for both backplanes is also the
same.
The PCI-Express I/O Backplane comprises two logically independent I/O circuits (partitions) on
one physical board:
• The I/O chip in cell location zero and its associated four PCI-X ASICs, four PCIe ASICs, and
their respective PCI/PCI-X/PCIe slots form PCI-Express I/O partition 0 plus core I/O.
• The I/O chip in cell location one and its associated four PCI-X ASICs, four PCIe ASICs, and
their respective PCI/PCI-X/PCIe slots form PCI-Express I/O partition 1 plus core I/O.
PCI-X/PCIe I/O Backplane 19