User Service Guide, Fifth Edition - HP Integrity rx8640 SEU
Unloading with a Lifter
Use the following procedure to unload the SEU from the pallet using a lifter.
WARNING! Use caution when using a lifter. Because of the weight of the SEU, it must be
centered on the lifter forks before raising it off the pallet to avoid injury.
Never extend more than one server from the same cabinet while installing or servicing either an
SEU or another server product. Failure to follow these instructions could result in the cabinet
tipping over.
Figure 3-5 RonI Lifter
IMPORTANT: The SEU must be mounted in the same rack as the server to which it will be
connected. The unit must also be mounted directly above the server in the same rack cabinet.
Any SEU installed into a rack is shipped with equipment slides. The following Installation Guide
is provided with every set of slides: Installation Guide, HP J1530B, Rack Integration Kit (MPN
J1530–90003).
You may source this guide at the following website:
http://h18004.www1.hp.com/products/servers/proliantstorage/bcs-rackandpower/
mounting_information.html
Follow the steps in this installation guide to determine where and how to place the SEU into the
rack before proceeding with Step 1.
1. Follow the instructions on the outside of the server packaging to remove the banding and
carton top from the server pallet.
2. Remove all cartons from the pallet, leaving only the SEU.
3. Position the RonI lifter as shown in Figure 3-6.
38 Installing the Server Expansion Unit