User Service Guide, Fifth Edition - HP Integrity rx8640 SEU
Standby Power and Logging in to the MP
Housekeeping power (also known as standby power) is generated as soon as AC power is applied
to the server. Because the MP uses standby power, it is possible to login to the server MP even
when the power switch is in the OFF position. The power switch is a DC power switch that
controls +48V DC.
NOTE: Connection to the MP is performed through the core I/O card installed in the server.
1. On the front of the server, a solid green Standby Power, and a solid green MP Present light
will illuminate after about 30 seconds.
Figure 3-26 Front Panel Display
2. Verify the bulk power supply LED for each BPS.
When on, the breakers distribute power to the BPSs. AC power is present at the BPSs under
the following conditions:
• When power is first applied, the BPS LEDs will be flashing amber.
• After 30 seconds has elapsed the flashing amber BPS LED for each BPS becomes a
flashing green LED
3. Login to the server MP:
a. Enter Admin at the login prompt. This term is case sensitive.
b. Enter Admin at the password prompt. This term is case sensitive.
The MP Main Menu appears:
Figure 3-27 MP Main Menu
Cabling and Power Up 65