Windows Integrity Enterprise Edition Release Notes

Release Notes
Troubleshooting common issues
HP Integrity Servers with Microsoft® Windows® Server 2003, Enterprise Edition
34
all Integrity
servers
Smart Array 640x/530x controllers do not automatically rebuild the internal HDD array
when a failed drive is replaced
Issue Smart Array 530x/640x controllers do not automatically rebuild the internal disk
array when failed drives are replaced. The server backplane does not provide the
manageability features needed for Smart Array adapters to recognize when drives
are hot inserted into the system.
Workaround By installing the Smart Array Rescan Service, the rebuild is initiated
automatically after drive replacement:
1. Download and flash the latest Smart Array firmware available from
www.hp.com/support/itaniumservers. NOTE: Minimum firmware
revision for the SA640x controller is 2.28. Minimum firmware revision for the
SA530x controller is 3.56.
2. Download and install the latest Array Configuration Utility (ACU-XE) from
www.hp.com/support/itaniumservers. The minimum required
revision for the ACU-XE is 7.15.18.0.
3. Download and install the Smart Array Rescan Service from
www.hp.com/support/itaniumservers. The minimum required
revision for the Rescan Service is 0.1.
4. If an internal HDD array fails, replace the failed physical drive. The Rescan
Service will initiate the rebuild automatically (it may take up to 5 minutes
before the rebuild starts). To start the rebuild immediately, open the Array
Configuration Utility (ACU-XE) and select Refresh in the Controller State
field, and the failed array will begin to rebuild.
all Integrity
servers
Smart Array 640x hot add is not supported
Issue If a Smart Array 6402 or 6404 card is hot-added to a slot, the card will not
function and a yellow exclamation mark displays next to the corresponding device
in the Device Manager. Furthermore, any SA640x card added in this manner
cannot be safely removed from the system without a reboot.
Workaround Hot adding is not currently supported for Smart Array 640x on HP Integrity
servers. Normal hot add procedures can be used to insert the card, but it will not
function until the next reboot. NOTE: Hot add is fully supported on SA530x.
all Integrity
servers
Smart Array 6400 controller cannot be hot replaced during error message display
Issue The Smart Array 6400 controller cannot be hot replaced when the following error
message displays: The device ‘Smart Array 6400’ cannot be
stopped because a program is still accessing it.
Workaround Restart the Storage Agents service and try to hot replace the controller again.