Windows Integrity Management Agents Reference

Event DescriptionEvent SeverityEvent ID
Drive Array Accelerator Status Change. The array accelerator board attached to the
array controller in %4 has a new status of %2.%n(Accelerator status values: 1=other,
2=notConfigured, 3=enabled, 4=tmpDisabled, 5=permDisabled)%n [SNMP TRAP:
3038 in CPQIDA.MIB]Warning1204
Drive Array Accelerator Bad Data. The array accelerator board attached to the array
controller in %4 is reporting that it contains bad cached data.%n [SNMP TRAP: 3039
in CPQIDA.MIB]Warning1205
Drive Array Accelerator Battery Failed. The array accelerator board attached to the
array controller in %4 is reporting a battery failure.%n [SNMP TRAP: 3040 in
CPQIDA.MIB]Warning1206
Drive Array Tape Library Status Change. The tape library in %4, SCSI bus %5, SCSI
target %6 has a new status of %7.%n(Library status values: 1=other, 2=ok, 3=degraded,
4=failed, 5=offline)%n [SNMP TRAP: 3041 in CPQIDA.MIB]Warning1207
Drive Array Tape Library Door Status Change. The tape library in %4, SCSI bus %5,
SCSI target %6 has a new door status of %7.%n(Library door status values: 1=other,
2=notSupported, 3=closed, 4=open)%n [SNMP TRAP: 3042 in CPQIDA.MIB]Warning1208
Drive Array Tape Drive Status Change. The tape drive in %4, SCSI bus %5, SCSI
target %6 has a new status of %7.%n(Tape drive status values: 1=other, 2=ok,
3=degraded, 4=failed, 5=offline, 6=missingWasOk, 7=missingWasOffline)%n [SNMP
TRAP: 3043 in CPQIDA.MIB]Warning1209
Drive Array Tape Drive Cleaning Required. The tape drive in %4, SCSI bus %5, SCSI
target %6 requires cleaning.%n [SNMP TRAP: 3044 in CPQIDA.MIB]Warning1210
Drive Array Tape Drive Replace Cleaning Tape. The cleaning tape in the tape drive
in %4, SCSI bus %5, SCSI target %6 needs to be replaced.%n [SNMP TRAP: 3045 in
CPQIDA.MIB]Warning1211
Storage System Fan Status Change.%nThe %6 %7 storage system connected to SCSI
bus %5 of the controller in %4 has a new status of %2.%n(Fan status values: 1=other,
2=ok, 3=failed, 4=notInstalled, 5=degraded)%n [SNMP TRAP: 8026 in CPQSTSYS.MIB]Warning1212
Storage System Temperature Status Change.%nThe %6 %7 storage system connected
to SCSI bus %5 of the controller in %4 has a new temperature status of
%2.%n(Temperature status values: 1=other,2=ok,3=degraded,4=failed,5=notInstalled)
%n [SNMP TRAP: 8027 in CPQSTSYS.MIB]Warning1213
Storage System Fault Tolerant Power Supply Status Change.%nThe fault tolerant
power supply in the %6 %7 storage system connected to SCSI bus %5 of the controller
in %4 has a new status of %2.%n(Power supply status values:
1=other,2=ok,3=degraded, 4=failed,5=notInstalled)%n [SNMP TRAP: 8028 in
CPQSTSYS.MIB]Warning1214
Fibre Channel Controller Status Change. The Fibre Channel Controller in %4 has a
new status of %5.%n(Host controller status values: 1=other, 2=ok, 3=failed,
4=shutdown, 5=connectionDegraded, 6=connectionFailed)%n [SNMP TRAP: 16028
in CPQFCA.MIB]Warning1215
Drive Array Physical Drive Status Change. The physical drive in %4, %5 with serial
number "%7", has a new status of %2. %n(Drive status values: 1=other, 2=ok, 3=failed,
4=predictiveFailure) %n [SNMP TRAP: 3046 in CPQIDA.MIB]Warning1216
Drive Array Spare Drive Status Change. The spare drive in %4, %5 has a new status
of %2.%n(Spare status values: 1=other, 2=invalid, 3=failed, 4=inactive,
5=building,6=active) %n [SNMP TRAP: 3047 in CPQIDA.MIB]Warning1217
Storage System Fan Status Change.%nThe %6 %7 storage system connected to %5
of the controller in %4 has a new status of %2.%n(Fan status values: 1=other, 2=ok,
3=failed, 4=notInstalled, 5=degraded)%n [SNMP TRAP: 8029 in CPQSTSYS.MIB]Warning1218
124 Management Agents Event Tables