HP Integrity Superdome 2 User Service Guide

Diagnostic Status:
Internal Data OK
Device Failure OK
Power Cord OK
Indicted OK
Similar information will be displayed for all other power supplies.
Collecting power status information for components at the compute enclosure
Use the show xfm status all, show blade status all, and show interconnect
status all commands to gather information on compute enclosure component power:
NOTE: Similar information should be displayed for XFMs 2 through 4.
sd-oa1> show xfm status all
Bay 4 XFM Status:
Health: OK
Power: On
Unit Identification LED: Off
Diagnostic Status:
Internal Data OK
Management Processor OK
Thermal Warning OK
Thermal Danger OK
Power OK <<<<
Firmware Mismatch OK
Indicted OK
Link 1: OK
Link 2: OK
Link 3: OK
Link 4: OK
Link 5: OK
Link 6: OK
Link 7: OK
Link 8: OK
sd-oa1> show blade status all
Blade #1 Status:
Power: On
Current Wattage used: 1325 Watts
Health: OK
Unit Identification LED: Off
Diagnostic Status:
Internal Data OK
Management Processor OK
Thermal Warning OK
Thermal Danger OK
I/O Configuration OK
Power OK <<<
Cooling OK
Device Failure OK
Device Degraded OK
Device Info OK
Firmware Mismatch OK
PDHC OK
Indicted OK
sd-oa1> show interconnect status all
Interconnect Module #1 Status:
Status: OK
Thermal: OK
CPU Fault: OK
Health LED: OK
Methodology 51