HP Integrity Superdome 2 User Service Guide
NOTE: When calculating the Power Limit Watts ac value, derate the circuit to 80% of
the maximum to prevent tripping the circuit breaker (United States only).
NOTE: If your facility cannot support the calculated peak Watts ac, set the Power Watts
ac value to match the capability of your facility.
• Dynamic Power —The default setting is Enabled. The following selections are valid:
Enabled —Some of the power supplies can be automatically placed on standby to
increase overall enclosure power subsystem efficiency.
◦
◦ Disabled —All power supplies share the load; the power subsystem efficiency varies
based on load.
• OA1 IP Addr— The default setting is DHCP; if no IP address is received, the IP address
is 0.0.0.0. The IP address, mask, and gateway are set within this option.
• OA2 IP Addr— If this module is present, the default setting is DHCP; if no IP address is
received, the IP address is 0.0.0.0. If only one Onboard Administrator module is installed,
then the screen displays “Not Present”.
• Enclosure Name— The default setting is a unique factory-assigned name. The accepted
character values are 0-9, A-Z ,a-z, -, _, and the box character. The box character is used
to signal the end of the name.
NOTE: Do not use the box character in the middle of a text box. Entries in text boxes
are truncated to the last character before the box character.
TIP: Select Clear from the navigation bar to quickly clear entries in text boxes up to the
symbol.
• Rack Name — The default setting is UnnamedRack. The accepted character values are
0-9, A-Z, a-z, -, _, and the box character. The box character is used to signal the end of
the name.
• DVD Drive— The DVD connection Settings screen is a table of all the servers with the
status of DVD Connection and blade name for that blade.
Running the Insight Display installation 35