nPartition Administrator's Guide, Second Edition

Table 7-1 Hardware Management Task Summaries
SummaryTask
CAUTION: Before powering off system hardware, you first must check whether it
is being used and also inspect the hardware.
Cabinet Power Switch: use the 48-volt power switch on the front of the cabinet.
Service Processor (MP or GSP): PE command.
See “Powering Server Cabinets On and Off (page 205).
“Powering Server
Cabinets On and Off
NOTE: Powering on a cell also powers on any I/O chassis attached to the cell, and
powering off a cell also powers off any I/O chassis attached to the cell. Powering on
or off an I/O chassis connected to a powered-on cell causes the cell to reset if the cell
located and mapped the I/O chassis during its cell boot process.
Service Processor (MP or GSP): PE command.
nPartition Commands: frupower command, and specify -o or -f and a cell or I/O
chassis: -o option to turn power on, -f option to turn power off, -c# for a cell (where
# is the cell number), -i #/#/# for an I/O chassis (where #/#/# is the
cabinet/bay/chassis).
Partition Manager:
Version 1.0 Select an inactive cell or I/O chassis, and use the CellPower Off
Cell or I/OPower Off I/O Chassis action (or a similar "Power On..." action).
Version 2.0 Select an inactive cell or I/O chassis, and use the CellPower Off
Cell or I/OPower Off I/O Chassis action (or a similar "Power On..." action).
See “Powering Cells and I/O Chassis On and Off (page 206).
“Powering Cells and I/O
Chassis On and Off
nPartition Commands: fruled command and specify -o or -f and a cabinet, cell, or
I/O chassis: -o option to blink the LED, -f option to turn off the LED, -b# for a cabinet
(where # is the cabinet number), -c# for a cell (where # is the cell number), -i #/#/#
for an I/O chassis (where #/#/# is the cabinet/bay/chassis)
HP-UX B.11.11 supports the rad command for controlling PCI card slot attention
indicators and other tasks.
HP-UX B.11.23 and HP-UX B.11.31 support the olrad command for controlling PCI
card slot attention indicators and other tasks.
Partition Manager:
Version 1.0 Select a cell or I/O chassis, and use the CellLight Cell LED or
I/OLight I/O Chassis LED action. To turn off all LEDs use the ComplexClear
All LEDs action.
Version 2.0 Select a cell or I/O chassis, and use the CellTurn On Cell LED or
I/OTurn On Chassis LED action (or a similar "Turn Off..." action). To turn off
all LEDs use the ComplexClear All LEDs action.
See “Turning Attention Indicators (LEDs) On and Off (page 209).
“Turning Attention
Indicators (LEDs) On and
Off
202 Managing Hardware Resources