nPartition Administrator's Guide, Second Edition

Table 8-1 Hardware and nPartition Status Task Summaries
SummaryTask
Service Processor (MP or GSP): CP command for cell nPartition assignments. PS
command and select a cell for detailed information about any cell in the complex.
nPartition Commands: parstatus -C command.
Partition Manager:
Version 1.0 DetailsShow Complex Details action, Cells tab.
Version 2.0 Select the Cells tab.
See “Listing Cell Configurations” (page 226).
“Listing Cell
Configurations”
Service Processor (MP or GSP): PS command, and select the cell whose processor
configuration you wish to view.
BCH Menu: Information menu, PR command.
EFI Shell: info cpu command.
nPartition Commands:
parstatus -C for processor summaries for all cells.
parstatus -V -c# for detailed processor information for the specified cell (-c#
where # is the cell number).
Processor information about the local nPartition: ioscan -C processor (HP-UX
only) or mpsched -s (HP-UX B.11.23 and HP-UX B.11.31).
Partition Manager:
Version 1.0 DetailsShow Complex Details action, CPUs/Memory tab.
Version 2.0 Select the Cells tab.
See “Listing Processor Configurations” (page 227).
“Listing Processor
Configurations”
Service Processor (MP or GSP): PS command, and select the cell whose memory
configuration you wish to view.
BCH Menu: Information menu, ME command.
EFI Shell: info mem command, and the dimmconfig # command (where # is the
cell number) for memory module (DIMM) details for a specific cell.
nPartition Commands:
parstatus -C for memory summaries for all cells.
parstatus -V -c# for detailed memory information for the specified cell (-c#
where # is the cell number). Includes cell local memory (CLM) details.
parstatus -V -p# for detailed memory information for the specified nPartition
(-p# where # is the nPartition number). Includes cell local memory (CLM) details.
Partition Manager:
Version 1.0 DetailsShow Complex Details action, CPUs/Memory tab.
Version 2.0 Select the Cells tab.
See “Listing Memory Configurations” (page 229).
“Listing Memory
Configurations”
Service Processor (MP or GSP): IO command to list connections from cells to I/O
chassis. PS command and the cabinet option to list I/O details for an entire cabinet.
BCH Menu: Information menu, IO command.
EFI Shell: info io command.
nPartition Commands: parstatus -I command, for complex-wide details.
HP-UX B.11.11 rad -q command.
HP-UX B.11.23 and HP-UX B.11.31 olrad -q command.
Partition Manager:
Version 1.0 DetailsShow Complex Details action, I/O Chassis tab.
Version 2.0 Select the I/O tab.
See “Listing Input/Output (I/O) Configurations” (page 231).
“Listing Input/Output
(I/O) Configurations”
224 Listing nPartition and Hardware Status