nPartition Administrator's Guide, Second Edition

-rcell
Specifies the core cell choices. One to four cells can be
specified.
-T flag
Specifies whether Hyper-Threading should be enabled or
not (only if cells support this feature). By default
Hyper-Threading is disabled.
The valid values for flag are:
y
Enable Hyper-Threading, which allows multiple
threads to run concurrently on each processor core.
n
Disable Hyper-Threading. This is the default value.
-B
Specifies to boot the nPartition. The default is not to boot
the nPartition and leave it in the shutdown for reconfig
state.
-u username
Enhanced nPartition Commands only. Specifies the account
and authorization to access an nPartition other than the
local nPartition.
The -h option is required if this option is used.
username specifies a configured user name on the target
nPartition.
-g
Enhanced nPartition Commands only. Allows access to
the complex specified by the -h option. The accessed
complex is then considered the target complex. Access is
through the service processor LAN port.The -h option is
required if this option is used.
-h IPaddress|hostname
Enhanced nPartition Commands only. This option is only
used in combination with either the -u or -g option.
IPaddress|hostname specifies the IP address or hostname of
the target nPartition (-u) or service processor (-g).
parcreate Command 251