HP-UX GUID Manager v1.0 Administrator Guide

The following commands update the WWNs data field (which is an optional task):
# /opt/guid/bin/guidmgmt -d wwn 50014C20000000 atcuxvm5
# /opt/guid/bin/guidmgmt -d wwn 50014C2000000001 atcuxvm5
# /opt/guid/bin/guidmgmt -q wwn | head -l 0
Address Type Owner Status Data
================ ========== ========== ========== ==========
50014C2000000000 wwn HPVM INUSE atcuxvm5
Address Type Owner Status Data
================ ========== ========== ========== ==========
50014C2000000001 wwn HPVM INUSE atcuxvm5
The data field is optional. It is a placeholder where information can be stored regarding a particular
WWN. For example, an administrator can put the size of the storage in the data field or put in
an organization name.
NOTE: If you use the same WWN on two different VSPs, you receive a warning that GUIDs are
INUSE or the GUIDs have been released by another VSP.
INUSE means that another guest in the GUID managed environment has configured those
WWNs to their NPIV HBA.
EXCLUDED means that another guest in the GUID managed environment had at one time used
those WWNs and has released them back to the GUID server.
For information about NPIV and the products with which it is integrated, see the following manuals
at http://www.hp.com/go/virtualization-manuals:
HP Integrity Virtual Machines V4.3: Release Notes (January 2012 patch release)
HP-UX Virtual Partitions v6.0 Administrator Guide
HP-UX vPars and Integrity VM V6.1 Administrator Guide
.
22 Integrating GUIDMgr