HP IP Distance Gateway Release Notes (5697-1529, January 2012)
Table Of Contents

• HP P9000 Continuous Access XP
• HP P9000 XP Array Manager
• HP P10000 3PAR V-Class, F-Class, T-Class
Operating systems and multipath support
The mpx110 supports all P6000 and P9000 Continuous Access supported operating systems and
multipath software. For additional information, see the HP Continuous Access documentation on
the HP website:
nl
http://www.hp.com/storage
You can also access the HP Enterprise Virtual Array compatibility reference on the HP website:
nl
http://h18006.www1.hp.com/products/storage/software/conaccesseva/index.html
Fixes and enhancements
The following fix and enhancement are included in firmware version 2.4.4.5:
• Correction for an error log overwrite issue
• Parity error entries are now displayed in the error log file
Prerequisites
The following prerequisites must be met to install firmware version 2.4.4.5:
• HP mpx Manager version 2.0.30, build 127 (minimum)
• Local and remote P6000/EVA, P9000/XP, or P10000/3PAR storage systems
• Local and remote B-series, C-series, or H-series Fibre Channel fabrics
• Dedicated IP network for FCIP connectivity
Installation instructions
For information about installing these products, see the HP IP Distance Gateway quick start
instructions and the HP IP Distance Gateway user guide, available on the HP website:
nl
http://h18006.www1.hp.com/products/storageworks/fcipd_gateway/index.html
At the website, under Support, select Support for your product, and then under Resources for HP
IP Distance Gateway, select Manuals.
Important information
This section contains important information about the current release.
CLI and mpx manager GUI display time difference
When the mpx110 time is changed using the date command in the CLI, the CLI will display the
correct local time of the mpx110. However, the mpx manager GUI will offset the mpx110 time
with its local host time zone, resulting in display of a different time.
E_Port unknown with B-series Fibre Channel switches using firmware version 5.2.0x
When connecting two B-series fabrics through FCIP using IP Distance Gateways, Fibre Channel
switches with firmware 5.2.0x may not connect successfully, in which case they will report E_Port
unknown.
Workaround
Depending on your B-series Fibre Channel switch model, use a supported switch firmware version
other than 5.2.0x.
4