11.5 HP StoreVirtual Storage Release Notes

Remote Copy
While cross–version Remote Copy is occurring from 10.0 or later to 8.5 management groups, if
copying halts because the cluster is full, the CMC displays the "See Alarms Window" error message,
although the 8.5 management group does not have the Alarms window
The Version 9.x and greater Alarms and Events feature is not compatible with pre-9.x versions of
software. Review the Alarms window for Version 9.x or later management groups. If you are
operating in a mixed SAN environment with management groups earlier than Version 9.x, also
review the Alerts window.
Microsoft System Center Virtual Machine Manager (SCVMM) Integration
SCVMM 2012 R2 is not supported
The StoreVirtual release versions 11.0 and 11.5 do not support SCVMM 2012 R2.
Provisioning FC storage to clustered Hyper-V hosts running Windows Server 2012 fails
Provisioning Fibre Channel storage to a clustered Windows 2012 Server Hyper-V cluster fails
with the message, SM_RC_UNKNOWN_ERROR.
Fibre Channel is not supported with SCVMM for the 11.5 release.
Cannot automatically provision volumes with CHAP authentication
CHAP cannot be automatically configured on volumes created with SCVMM. This is because of
the SMI-S standard, rather than an issue with either SCVMM or the StoreVirtual storage system.
To use CHAP, follow the instructions in the HP StoreVirtual Storage User Guide to configure CHAP
manually.
Deleting a stored virtual machine does not delete the storage
To resolve this issue, use the CMC to identify and delete any stranded SmartClones.
After registering a provider and creating a LUN, the Available Capacity value for a storage pool
is not correct
The value displayed in the Available Capacity column for a Storage Pool (LeftHand OS Cluster)
is not correct in Fabric\Storage\Classifications and Pools in the SCVMM GUI. To resolve this
issue, manually refresh or manually rescan the provider in the Fabric\Storage\Providers node
(SCVMM UI).
Running Register-SCStorageLogicalUnit on an array of LUNs causes the LUNs to be
assigned to multiple storage groups
A single LUN can belong to only one storage group. If the commandlet
Register-SCStorageLogicalUnit is run on an array of LUNs, then the
Get-SCStorageLogicalUnit on a particular volume will return an invalid configuration.
To fix this issue, perform the following steps:
1. Unregister the volumes using the command Unregister_SCStorageLogicalUnit.
2. Run the SCStorageLogicalUnit commandlet again on each individual volume.
Storage Migration does not delete the source storage; it is copied instead of moved
When migrating the storage of a virtual machine from one volume to another, the original storage
is not totally removed and will display in both locations.
Update-StorageProviderCache fails with a Timeout
If running the commandlet Update-StorageProviderCache -Discoverylevel Full
and more then one storage provider is registered, it results in the following error message:
Update-StorageProviderCache : Timeout.
Workarounds 23