HP StorageWorks P4000 Series SAN Solution Upgrade Instructions (AX696-96010, March 2010)
Download the upgrade components
Use Table 2 to determine the appropriate upgrade files for your storage nodes.
Table 2 Upgrade paths available for SAN/iQ software version 8.5
Use Upgrade File
For SAN/iQ Software
Version
Platform
SANiQ_8.5.00.0319_20100326_all.upgrade
(AX696-10509)
7.0.xx.xxxx or greater• HP StorageWorks P4500 G2
• HP StorageWorks P4300 G2
• HP LeftHand P4500
• HP LeftHand P4300
• VSA
• HP DL 320s
• HP DL 380
• NSM 2120 G2
• NSM 2120
• NSM 2060 G2
• NSM 2060
• NSM 4150
• NSM 260
• NSM 160
• IBM 3650
• Dell 2950
Increase the size of the OS disk on both VSAs and Failover Managers
Due to changes in the size of the VMware tools that get installed during this software upgrade, you
must increase the size of the OS disk before upgrading the VSA and the Failover Manager. Additional
space requirements are necessary for future software releases, as well. Therefore, we recommend
increasing the size of the OS disk to accommodate both requirements at this time.
NOTE: These instructions apply to VMware ESX Server. Other VMware products have similar
instructions for extending a virtual disk. Please consult the appropriate VMware documentation for
the product you are using
To increase the OS disk size on the VSA:
1. Using the CMC, power off the VSA.
2. Open the VI Client and select VSA -> Edit Settings -> Hardware.
3. Select Hard disk 1 (verify that the Virtual Device Node is SCSI (0:0)).
4. Under Disk provisioning, changed the provisioned size to 8 GB.
5. Click OK.
6. Repeat these steps for Hard disk 2 (verify the Virtual Device Node is SCSI (0:1))
7. Using the VI Client, power on the VSA.
8. Find the VSA in the CMC and apply the 8.5 upgrade.
To increase the OS disk size on the Failover Manager:
P4000 SAN/iQ software upgrade user guide 11