HP StorageWorks LUN Configuration and Security Manager XP user guide for the XP12000/XP10000/SVS200 LUN Manager and Volume Manager (T1714-96015, October 2007)

NOTE:
If nothing appears in the LU Path table, select a host group (
)inthetree.
•The
icon indica
tes a logical volume to which command device security is already
applied.
•The
icon does not indicate any logical device.
3. Select Cmd. Dev. Security: Disable -> Enable.Aconrmation message appears.
4. Click OK.
5. Click Apply.Aconrmation message appears.
6. Click OK. Settings are applied to the array.
NOTE:
To remove command device security from a logical device, right-click the logical device (
)intheLU
Path or LDEV table, and select Cmd. Dev. Security: Enable -> Disable.
Dening remote command devices
A remote command device is a device in the array to which a command device in the external array
is mapped
.
As you send RAID Manager XP commands to the remote command device, these RAID Manager XP
commands are sent to the external array's command device to perform RAID Manager XP operations
on the external array.
You can ma
p a command device as a remote command device when one of the following arrays is
connected as an external array:
XP12000 Disk Array
XP10000
Disk Array
HP 200 Storage Virtualization System
XP1024/XP128 Disk Array
TagmaSt
ore Universal Storage Platform subsystem
TagmaStore Network Storage Controller subsystem
TagmaStore Adaptable Modular Storage subsystem
TagmaS
tore Workgroup Modular Storage subsystem
Lightning 9900V series subsystem
Thunder 9500V series subsystem
For mo
re information about dening remote command devices, see the HP StorageWorks External
Storage XP user guide.
Conguring Fibre Channel ports
UsethePortpane(Figure 21)tocongure Fibre Channel ports in the array. You can also use this pane to
modify the port conguration when the system is operating.
108