HP StorageWorks LUN Configuration and Security Manager XP user guide for the XP12000/XP10000/SVS200 LUN Manager and Volume Manager (T1714-96015, October 2007)

Initializing iS
CSI target 0 (zero)
If you follow th
e procedure below, iSCSI target 0 (zero) is set to its initial state. This procedure removes
all LU paths related to iSCSI target 0. This procedure also changes iSCSI target 0's host mode to
Standard and initializes the iSCSI target name. After this procedure, the iSCSI target's name changes to
its default name.
1. Start LUN Manager. The LUN Manager pane (Figure 15) appears.
2. In the tree, ri
ght-click iSCSI target 0, which is preceded by 00,andselectClear Host Group.A
conrmation
message appears.
3. Click YES.
iSCSI target 0's host mode and host group name are changed in the tree. iSCSI names are also
removed from iSCSI target 0.
LU paths are removed from the table on the right of the tree. LUNs corresponding to removed LU
paths appea
rinblue.
4. Click Apply.Aconrmation message appears.
5. Click OK. Changes are applied to the array.
Changing a host bus adapter's WWN and nickname
In Fibre Channel environments, you can identify host bus adapters by WWNs or nicknames.
1. Start LUN Manager. The LUN Manager pane (Figure 14)appears.
2. In the tree, double-click the Fibre folder. A list of Fibre Channel ports appears.
3. Inthetree,double-clicktheFibreChannelporttowhichthehostbusadapterisconnected.
4. In the tree, right-click a host bus adapter (
), and select Change WWN & Nickname.TheChange
WWN & Nic
kname dialog box appears.
Figure 51 Change WWN & Nickname dialog box
5. To change the WWN, enter a new WWN or select another WWN from the WWN list.
To change the nickname, enter a new nickname In the Nickname box.
6. If necessary, select Apply this change to other ports, too.
If this check box is selected, the change in the pane also affects other ports. For example, suppose
that the same host bus adapter (that is, the same WWN) is located below ports CL1-A and CL2-A in
the tree. If you select the host bus adapter (or WWN) from below one of the ports and change the
nickname to hba1, the host bus adapter below the other port is also renamed to hba1.
HP StorageWorks LUN Conguration and Security Manager XP user guide for the
XP12000/XP10000/SVS200
97