HP Insight Management 7.3 Support Matrix
Table Of Contents
- HP Insight Management 7.3 Support Matrix
 - Contents
 - 1 New and deprecated support
 - 2 Management servers
 - 3 Management servers in a high-availability environment
 - 4 Managed systems hardware
- Public cloud providers
 - Supported HP BladeSystem enclosures
 - Supported servers
 - Supported storage products
 - Supported hardware network products
 - HP Virtual Connect Enterprise Manager hardware
 - Other supported hardware
 
 - 5 Managed system firmware
 - 6 Managed systems software
 - 7 Managed systems agents and providers
 - 8 Support and other resources
- Information to collect before contacting HP
 - How to contact HP
 - Security bulletin and alert policy for non-HP owned software components
 - Registering for software technical support and update service
 - HP authorized resellers
 - New and changed information in this edition
 - Related information
 - Typographic conventions
 
 - 9 Documentation feedback
 - A Hardware requirements and supported capabilities for Insight Control power management
 - B Hardware requirements and caveats for Insight Control server migration
- Storage controllers that Insight Control server migration supports
 - Converged network adapters that Insight Control server migration supports
 - Network interface cards that Insight Control server migration supports
 - File system types that Insight Control server migration supports
 - Caveats for Linux server migrations
 - Supported storage adapters for manual boot of a destination virtual machine
 - Additional Insight Control server migration information
 
 - C Hardware requirements and caveats for Insight Control server provisioning
 - D HP-UX CMS requirements
 - Acronyms and abbreviations
 - Index
 

Table 64 Requirements and capabilities for HP ProLiant ML servers (continued)
Intelligent
Power
Discovery
3
Data
Center
Power
Control
1,2
Calibrated
Maximum
Power
Power
Metering
Data
Center
Thermal
Mapping
Dynamic
Power
Capping
Power
Regulator
Minimum
system BIOS
version
Minimum
iLO
firmware
version
Server
model
✓✓✓✓✓✓NoneNoneProLiant
ML330
G6
5
✓✓✓✓✓
6
✓5/1/2007iLO 2
version
ProLiant
ML350 G5
1.30 or
later
✓✓✓✓✓✓✓D22
2/23/2009
iLO 2
version
ProLiant
ML350 G6
1.79 or
later
✓✓✓✓✓✓✓iLO 4
version
ProLiant
ML350e
Gen8 1.01 or
later
07/04/2013iLO 4
version
1.30
ProLiant
ML350e
Gen8 V2
✓✓✓✓✓✓✓iLO 4
version
ProLiant
ML350p
Gen8 1.01 or
later
✓✓✓✓✓✓✓P72
08/26/2013
iLO 4
version
ProLiant
ML350p
1.30 or
later
Gen8 (with
Intel EP v2
Xeon
processor)
✓✓✓✓
6
✓5/1/2007iLO 2
version
ProLiant
ML370 G5
1.30 or
later
✓✓✓✓✓✓✓P63
6/20/2009
iLO 2
version
ProLiant
ML370 G6
1.79 or
later
1
Data Center Power Control works only on Primary Addresses of a system and cannot detect a system with a non-primary
address. If a system has IPV4 as a primary address and IPV6 as a non-primary address, Data Center Power Control only
works with the IPV4 address.
2
For VMhost with only an IPV6 address. Data Center Power Control cannot perform a graceful shutdown of guests. It will
only shutdown the hosts.
3
The Intelligent Power discovery feature is not supported when iPDU is configured with iPV6 addresses only
4
You can purchase the RPS option to enable Dynamic Power Capping on this server.
5
This server supports only power/thermal monitoring and capping with certain power-supply options. For detailed
requirements, see the server QuickSpecs.
6
This server supports only Power Capping. It does not support Dynamic Power Capping.
Server requirements and supported capabilities for Insight Control power management 79