HP Matrix infrastructure orchestration: ESXi OS Deployment
Technical white paper: ESXi OS Deployment 
4 
d.  After the above steps have been completed, move the physical server out of the IO Maintenance Server 
Pool into the Server Pool where it originally resided before the deletion request. 
Important 
If the host is the last remaining host in a cluster, manually erase the disk. Do not run an erase disk job when 
other hosts remain in the cluster, as 
the erase disk job will erase the shared disks
, and data loss will occur. 
Verify pre-requisites are met 
Before using this guide, verify that all pre-requisites are met. The HP Matrix Operating Environment (Matrix OE) must be 
installed and operational. In this example, Matrix OE version 7.3 Update 1 is used. VMware vCenter Server must be installed 
on a server other than the Central Management Server (CMS) or the deployment server, and must be operational. The 
vSphere Client must be installed and operational to access the vCenter Server. In this example, vCenter Server 5.5 and 
vSphere Client 5.5 are used. 
In this example, Virtual Connect Flex-10 Ethernet modules are installed in Bays 1 and 2. A single external network switch 
(a ProCurve Switch 3500yl-24G) is used. Optionally, two external network switches could be used for high availability. 
The Virtual Connect Flex-10 Ethernet modules are configured as in scenario 2:4, Flex-10 - VLAN Tagging (802.1Q) with 
Multiple Shared Uplink Sets (SUS) and Tunneled VLANs - ESX 4, in the HP Virtual Connect Ethernet Cookbook: Single and Multi 
Enclosure Domain (Stacked) Scenarios 
(http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01990371/c01990371.pdf
). Two shared uplink sets, 
which are presented to the server as separate networks, are defined to carry deployment, ESX console and ESX vMotion 
traffic. Additionally two vNet networks are defined to carry the multiple VLAN traffic of production networks that will be 
configured in ESX to be presented to virtual machine 
Two Shared Uplink Sets are defined: 
•  Bay 1, Port X1, and associated networks deployment, mgmt_A, and vMotion_A, are added to the first Shared Uplink Set 
(in this example, VLAN-Trunk-1) 
•  Bay 2, Port X1, and associated networks mgmt_B and vMotion_B, are added to the second Shared Uplink Set (in this 
example, VLAN-Trunk-2) 
Two vNet Ethernet Networks are defined, with VLAN tunneling enabled: 
•  Bay 1, Port X2 is added to the first vNet (in this example, prod_A) 
•  Bay 2, Port X2 is added to the second vNet (in this example, prod_B) 
The corresponding ports in the external network switches are configured to support the appropriate VLAN IDs (in this 
example, 101, 102, and 103) for the Shared Uplink Set associated networks (in this example, deployment, mgmt_A, 
mgmt_B, vMotion_A, and vMotion_B) and the VLANs of the production networks of the vNets (in this example, 2000, 2042, 
2309, 2740, and 2936). 
Note 
Optionally, additional networks may also be configured, such as a heartbeat network to provide high availability for the 
VMware vCenter Server or iSCSI connections
1
. 
The Virtual Connect configuration used in this example is summarized in the following tables. Table 1 summarizes the 
ethernet network configuration. 
1
 1 In the HP Matrix Operating Environment, iSCSI is supported as virtual machine guest storage. For more information, refer to the Insight Management Support 
Matrix (www.hp.com/go/matrixoe/docs) or the CloudSystem Matrix Compatibility Chart (www.hp.com/go/matrixcompatibility). 