SPM adapter for EMC® Symmetrix® VMAX®: Matrix support for automation of EMC storage operations via the HP Storage Provisioning Manager
Technical white paper 
SPM adapter for EMC® 
Symmetrix® VMAX® 
Matrix support for automation of EMC storage operations via the 
HP Storage Provisioning Manager 
Table of contents 
Introduction .................................................................................................................................................................................... 2 
Requirements ................................................................................................................................................................................. 2 
Hardware Requirements ......................................................................................................................................................... 2 
Software Requirements .......................................................................................................................................................... 2 
Installation ...................................................................................................................................................................................... 4 
Enabling and Disabling the EMC adapter ............................................................................................................................. 4 
Uninstall........................................................................................................................................................................................... 5 
Upgrade ........................................................................................................................................................................................... 6 
Configuration .................................................................................................................................................................................. 6 
Setting EMC SMI-S Credentials ............................................................................................................................................... 6 
Setting HTTP Timeout .............................................................................................................................................................. 6 
Setting EMC Director Ports ...................................................................................................................................................... 6 
Setting Flags on EMC Director Ports ..................................................................................................................................... 7 
Using Suitable EMC Ports for Provisioning .......................................................................................................................... 8 
Pre-Provisioning of Volumes and Thin Pools on EMC Symmetrix VMAX ...................................................................... 8 
Importing an EMC Symmetrix VMAX storage array into SPM .............................................................................................. 9 
Troubleshooting .......................................................................................................................................................................... 12 
Unable to connect to the remote server ............................................................................................................................ 12 
The remote server returned an error: (401) Unauthorized ........................................................................................... 13 
The operation has timed out ................................................................................................................................................ 13 
Failed to refresh resources from adapter 'EMCSymmVMax' ......................................................................................... 13 
Storage pool setting does not exist for the given RAID.................................................................................................. 13 
Growing thin volume feature is not supported ................................................................................................................ 13 
Specified target ports cannot be used for presentation ................................................................................................ 15 
The operation will result in consistent LUN violation ...................................................................................................... 15 
The LUN value is invalid because VSA is enabled............................................................................................................. 16 
Summary ....................................................................................................................................................................................... 17 
For more information ................................................................................................................................................................. 17 
Glossary ......................................................................................................................................................................................... 17 