Building Disaster Recovery Serviceguard Solutions Using Metrocluster with Continuous Access XP P9000 for Linux B.12.00.00
# run the raidscan command on ftsys1a or ftsys2a that is connected to the
# remote XP array.
# The HORCM_LDEV parameters are used to describe
# stable LDEV# and Serial# as another way of HORCM_DEV used 'port#,Target-ID,LUN'.
# [Note]:
# This feature depends on the micro version of RAID or kind of RAID.
# <dev_group>
# This parameter is used to define the device group name for paired logical
# volumes. The device group name is used by all Raid Manager commands for
# accessing these paired logical volumes.
# <dev_name>
# This parameter is used to define the names of the paired logical volumes
# in the device group.
# <Serial#>
# This parameter is used to describe the Serial number of RAID box.
# <CU:LDEV(LDEV#)>
# This parameter is used to describe the LDEV number in the RAID box,
# This parameter is used to describe the LDEV number in the RAID box,
HORCM_LDEV
#dev_group dev_name Serial# CU:LDEV(LDEV#) MU#
pkgA pkgA_index 60095 01:04 0
pkgA pkgA_logs 60095 01:05 0
pkgB pkgB_d1 60095 01:06 0
pkgC pkgC_d1 60095 01:07 0
pkgD pkgD_d1 60095 01:08 0
HORCM_INST
#dev_group ip_address service
pkgA ftsys1 horcm0
pkgB ftsys1 horcm0
pkgC ftsys1 horcm0
pkgD ftsys1 horcm0
Sample RAID Manager configuration file for the Virtual Command Device
This section includes a sample RAID Manager configuration file for the virtual command device.
For this sample, following are the configuration details:
• ftsys1 and ftsys2 are part of primary site
• ftsys1a and ftsys2a are part of recovery site
• horcm0 is the local array Raid manager
• 10.0.0.1 is the IP address of the service processor
• 31001 is the UDP communication port number
The following is an example of a RAID manager configuration file for one node (ftsys1).
## horcm0.conf.ftsys1- This is an example Raid Manager configuration
# file for node ftsys1.Note that this configuration file is for Raid
# Manager instance 0, which can be determined by the "0" in the filename
# "horcm0.conf".
# Whenever this configuration file is changed, you must stop and restart
# the instance of Raid Manager. This can be done using the following commands:
# horcmshutdown.sh <instance>
# horcmstart.sh <instance>
# After restarting the Raid Manager instance, you must confirm that there
# are no configuration errors reported by running the pairdisplay command
# with the "-c" option.
HORCM_MON
#ip_address service poll_interval(10ms) timeout(10ms)
ftsys1 horcm0 1000 3000
HORCM_CMD
\\.\IPCMD-10.0.0.1-31001
HORCM_DEV
#dev_group dev_name port# TargetID LUN#
68 Sample configuration files for Metrocluster with Continuous Access XP P9000 for Linux B.01.00.00