HP MPX200 Mutifunction Router Command Line Interface User Guide (5697-2512, May 2013)

1. To view the targets, issue the show presented_targets command:
MPX200 <1> (admin) #> show presented_targets
Presented Target Information
----------------------------
FC/FCOE Presented Targets
-------------------------
WWNN 20:04:00:c0:dd:18:c9:89
WWPN 21:04:00:c0:dd:18:c9:89
Port ID 03-01-02
Port FC2
Type FC
<MAPS TO>
Name iqn.2001-05.com.equallogic:0-8a0906-7e33e0d06-83c835550264bed
e-demo1
Figure 4 (page 100) shows the Fibre Channel switch GUI, where the zone of the newly mapped
target is configured with the MPX200 router to the Fibre Channel SAN.
Figure 4 iSCSI configured with router to Fibre Channel SAN
2. After the server discovers the storage and I/O has started, issue the show perf byte command
to determine what I/O is operational on the selected ports:
MPX200 <1> (admin) #> show perf byte
WARNING: Valid data is only displayed for port(s) that are not
associated with any configured FCIP routes.
Displaying bytes/sec (total)... (Press any key to stop
display)
GE1 GE2 10GE1 10GE2 FC1 FC2 FC3 FC4
-------------------------------------------------------------
0 0 102M 0 0 109M 0 0
0 0 106M 0 0 104M 0 0
100 Configuring Fibre Channel initiators to iSCSI storage