HP MPX200 Mutifunction Router Command Line Interface User Guide (5697-2512, May 2013)

Member 7 Type:Port Name Id:21:09:00:c0:dd:12:fe:52
FC Port 4 Zone Information
---------------------------
Link down, cannot retrieve zone information
shutdown
Shuts down the blade.
Authority
Admin session
Syntax
shutdown
Example
MPX200 <1> (admin) #> shutdown
Are you sure you want to shutdown the System (y/n): n
Command aborted.
smartwrite device
Removes the specified offline FC device from the list of available SmartWrite devices.
NOTE: The SmartWrite feature is not currently supported.
Authority
Admin session
Syntax
swdevice rm
Keywords
rm removes the selected offline FC device
Example
MPX6200 <1> (admin) #> swdevice rm
Index State (WWNN,WWPN/iSCSI Name)
----- ----- ----------------------
0 Online 20:00:00:18:62:6f:d7:7c,21:00:00:18:62:6f:d7:7c
1 Online 20:00:00:18:62:6f:d7:5e,21:00:00:18:62:6f:d7:5e
2 Offline 20:00:00:18:62:6f:d7:6f,21:00:00:18:62:6f:d7:6f
3 Offline 20:00:00:18:62:6f:d7:79,21:00:00:18:62:6f:d7:79
Please select an 'OFFLINE' Device from the list above ('q' to quit): 3
All attribute values that have been changed will now be saved.
shutdown 79