HP MPX200 Mutifunction Router Command Line Interface User Guide (5697-2512, May 2013)

6. Select Chap Login Information.
7. In Target Secret, type the secret (secret_initiator) that you created in Step 2.
8. Select Mutual Authentication.
9. Click OK twice.
The initiator completes the normal login.
Normal session for uni-directional CHAP
Follow this procedure to configure a uni-directional CHAP used during a normal session:
NOTE: Do not enable CHAP on the presented target.
1. Issue the initiator add command as follows:
a. Add the initiator that is about to do a normal login.
b. Enable the CHAP for this initiator.
c. Create a secret (for example, secret_initiator).
d. Issue the set chap command to update the CHAP settings of the initiator.
2. Go to the MS Initiator and click Targets.
3. Select the target you want to log into and click Advanced.
4. Select Chap Login Information.
5. In Target Secret, type the secret (secret_initiator) that you created in Step 1.
6. Click OK twice.
The initiator completes the normal login.
88 Configuring CHAP