Using the Configuration Wizard
The Configuration Wizard helps you initially configure the system or change system configuration settings.
The wizard guides you through the following steps. For each step you can view help by clicking the help icon in
the wizard panel. As you complete steps they are highlighted at the bottom of the panel. If you cancel the wizard at
any point, no changes are made.
Change passwords for the default users
Configure each controller’s network port
Enable or disable system-management services
Enter information to identify the system
Configure event notification
Configure controller host ports
Confirm changes and apply them
When you complete this wizard you are given the option to start the Provisioning Wizard to provision storage.
Step 1: Starting the wizard
1. In the Configuration View panel, right-click the system and select either Configuration > Configuration Wizard or
Wizards > Configuration Wizard. The wizard panel appears.
2. Click Next to continue.
Step 2: Changing default passwords
The system provides the default users manage and monitor.
1. To secure the storage system, set a new password for each default user. A password is case sensitive and must
contains 8-32 characters. A password cannot contain the following characters: angle brackets, backslash,
comma, double quote, single quote, or space. If the password contains only printable ASCII characters then it
must contain at least one uppercase character, one lowercase character, and one non-alphabetic character.
2. Click Next to continue.
Step 3: Configuring network ports
You can configure addressing parameters for each controller’s network port. You can set static IP values or use DHCP.
In DHCP mode, network port IP address, subnet mask, and gateway values are obtained from a DHCP server if one
is available. If a DHCP server is unavailable, current addressing is unchanged. You must have some means of
determining what addresses have been assigned, such as the list of bindings on the DHCP server.
Each controller has the following factory-default IP settings:
DHCP: enabled
Controller A IP address: 10.0.0.2
Controller B IP address: 10.0.0.3
IP subnet mask: 255.255.255.0
Gateway IP address: 10.0.0.1
When DHCP is enabled, the following initial values are set and remain set until the system is able to contact a DHCP
server for new addresses:
Controller A IP address: 10.0.0.2
Controller B IP address: 10.0.0.3
IP subnet mask: 255.255.255.0
Gateway IP address: 0.0.0.0