NOTE:
In dual-controller congurations, rmware on the two controllers is compared each time
the MSA chassis is restarted. If the versions are mismatched, the system prompts to clone
the rmware on the controller with the latest versi on over to the controller with the earlier
version rmware. The following message is displayed on the LC D panel of the controller
with the earlier rmware:
07 CLONE FIRMWARE ? ‘<‘ = NO, ‘>’ = YES
Press the > button on the LCD panel to clone the rmware. During the cloning process,
informational messages are displayed on the controller LCD panels. When the cloning
process is complete, the just-updated controller automatically restarts.
11. After the MSA startup process is complete, access the MSA Flash Utility again, click Find Devices,
and then read the display to verify that the rmware was updated.
12. Before resuming I/O ac cess to the MSA, verify that the MSA and its storage arrays are online.
13. Repeat these steps on other MSA that need updating.
Using the SCSI Command Utility (HP-UX)
NOTE:
ThefollowingHP-UXenvironmentscanusetheSCUtoupdateMSArmware:
active/passive MSA1000: currently-installed rmware must be v4.38 or v4.48.
active/passive MSA1500: currently-installed rmware must be v5.10 or later.
active/active MSA1000 or MSA1500: currently-installed rmware must be v6.xx or later.
If rmware other than the above listed versions is currently installed on the MSA, you cannot use the SCU
to update the rmwareontheMSA.YoumustusetheMSACLIdownload firmware offline
command. See Using the MSA CLI (most environments).
NOTE:
When migrating fr om acti ve/passive to active/active rmware, use the MSA CLI download firmware
offline command to upgrade the rmware. See Using the MSA CLI (most environments).
During the updating process, use the following table to enter information about your environment.
Table 6 H P-UX system information worksheet
Class
H/W path DSF
Driver
WWPN
Description
MSA controller rmware len
ames and path: ______________________________
HP StorageWorks 1000/1500 Modular Smart Array rmware updating guide
25