HP StorageWorks 1000/1500 Modular Smart Array Firmware Updating Guide (370881-001, May 2006)

Example command and response, using the sample information in Step 3:
# /usr/bin/scu -f /dev/rscsi/c5t0d0 download /tmp/scu/msav686b397.bin
save segment
Downloading File “msa686b397.bin” of 1048576 bytes...
Download completed successfully...
DELAYING FOR 120 SECONDS WHILE FIRMWARE IS SAVED, PLEASE BE PATIENT...
120
CAUTION:
Do not restart the server or the MSA until the rmware download process is complete.
NOTE:
The MSA LCD panel displays the message FIRMWARE FLASH STARTED when the
download b e g ins and FIRMWARE FLASH DONE when the download is complete.
6. Wait for the CLI p
rompt to redisplay .
7. Wait for FIRMWARE FLASH DONE to display on the MSA LCD panel.
8. Power cycle the MSA.
NOTE:
In dual-controller congurations, rmware on the two contr ollers is compared each time
the MSA chassis is restarted. If the v e rsions are mismatched, the system prompts to clone
the rmware on t
he controller with the latest version over to the c ontroller with the earlier
version rmware. The following message is displayed on the LCD p anel of the c ontroller
with the earlier rmware:
07 CLONE FIRMWARE ? ‘<‘ = NO, ‘>’ = YES
Press the > button on the LCD panel to clone the rmware. During the cloning process,
informational messages are displayed on the controller LCD panels. When the cloning
process is complete, the just-updated controller automatically restarts.
9. Verify that the controller rmware was updated by entering the SHOW INQUIRY comm and within the
SCU and reading the display.
Example command and response, using the sample information in Step 3:
28
Updating the components