HP StorageWorks 2312/2324 Modular Smart Array controller installation instructions (508933-001, January 2009)

3. Pull the blank st
raight out of the enclosure.
Install con
troller(s)
NOTE:
For clarity, only relevant details are shown in these illustrations.
1. Loosen the thumbscrews; press the latches downward.
2. Slide the controller into the enclosure as far as it will go (1).
3. Press the latches upward to engage the controller (2); turn the
thumbscrews nger-tight.
4. Connect cables according to a supported conguration. See the
user guide.
Upgrading an existing single controller
system to a dual controller
If you have an existing sin gle controller system and you are adding a
second controller, the new controller automatically begins to initialize
when it is installed. If the rmware versions differ between the t wo
controllers, P artner Firmware Upgrade feature brings the older rmware
to the later rmware level.
Verifying Partner Firmware Upgrade is
enabled
By default the s
torage system’s Partner Firmware Upgrade feature is
enabled, so whe
n you upgrade a controller the system automatically
ensures that b
oth controllers have the more recent version.
Log in to the co
mmand-line interface (CLI) and run the following
command to verify that Partner Firmware Upgrade is enabled.
show advanced-settings
If Partner Firmware Upgrade is disabled, enable it by running the
command:
set advanced-settings partner-firmware-upgrade
enabled
Verifying controller status
Once the controller completes initializing and is online:
Verify tha t the heartbeat LED on the front of the enclosure is green.
Verify that the OK LED on the back of the controller is green.
NOTE:
If the OK L
ED is blinking, the controller is still initializing.
Additional information
See the MSA web site: http://www.hp.com/go/msa.