MSL6000 series tape library user guide 115
3054 Need 1 Drive Minimum
(No available drive to run diag.)
Install or activate a drive.
Press the Enter button to clear the
message.
Invalid user initiated operation. Set
parameters correctly and try again.
3055 Memory Allocation Error
(Memory allocation error in diagnostic.)
Cycle power to the library or reboot by
using the LCD touch display. Wait 30
seconds to power up again.
3057 Invalid Magazine Type
(Unsupported magazine type detected.)
Upgrade firmware if a newer revision
exists.
Press the Enter button to clear the
message.
Check magazine type.
Invalid user initiated operation. Set
parameters correctly and try again.
3058 Magazine Type Change Not Handled
(Unsupported magazine type detected.)
Upgrade firmware if a newer revision
exists.
Press the Enter button to clear the
message.
Check drive type.
Invalid user initiated operation. Set
parameters correctly and try again.
3059 Drive Type Not Supported
(Unsupported magazine type detected.)
Upgrade firmware if a newer revision
exists.
Press the Enter button to clear the
message.
Invalid user initiated operation. Set
parameters correctly and try again.
3060 Zone Sequence Error Cycle power to the library or reboot by
using the LCD touch display.
Update the Map using the LCD touch
display. (Menu -> Maintenance -> Force
reconfiguration)
3061 Homing Error
(Unable to complete Shuttle Homing
Algorithm.)
Cycle power to the library or reboot by
using the LCD touch display.
Update the Map using the LCD touch
display. (Menu -> Maintenance -> Force
reconfiguration)
Table 10 Fault Symptom Codes (continued)
FSC Message ERP