Operation64
Table 6 View SCSI Options
Option Description
Drive 0 Bus ID Lets you set the SCSI addresses of drive 0. The designators
Drive 0 (outer tape drive) through Drive
n
refer to the first
through
n
th drives, counting from right to left starting with
the master unit in a scaled Library system. Default is 1.
Drive 1 Bus ID Lets you set the SCSI addresses of drive 1. The designators
Drive 1 (inner tape drive) through Drive
n
refer to the
second through
n
th drives, counting from right to left
starting with the master unit in a scaled Library system.
Default is 2.
Drive 2 Bus ID
(four-drive models
only)
Lets you set the SCSI addresses of drive 2. The designators
Drive 2 (lower, outer tape drive) through Drive
n
refer to
the third through
n
th drives, counting from right to left
starting with the master unit in a scaled Library system.
Default is 3.
Drive 3 Bus ID
(four-drive models
only)
Lets you set the SCSI addresses of drive 3. The designators
Drive 3 (lower, inner tape drive) through Drive
n
refer to
the fourth through
n
th drives, counting from right to left
starting with the master unit in a scaled Library system.
Default is 4.
Library SCSI Bus ID Lets you set the SCSI addresses for the library robotics. The
default is 0.
Library SCSI Bus Parity Lets you enable or disable the library robotics SCSI bus
parity checking. The default is Enabled.
Mail Slot Access This option controls access to the mail slot and media
removal. “Prevent Allow” Command Inhibits allows access
to the mail slot via the GUI control panel and allows
media removal. “Prevent Allow” Command Ignored
prevents access to the mail slot and removal of media. This
option is used for some backup applications. The default is
“Prevent Allow” Command Inhibits.
SCSI Mode Defines the loader as SCSI-2 or SCSI-3. The default is
SCSI-3.
Unit Attention
Reporting
Lets you select reporting of all or only one stacked-unit
attention conditions. If set to Report All, the unit reports all
unit attention conditions in sequence; if set to Report One,
the unit reports only the highest priority condition. The
default is Report All.