HP StorageWorks 1/8 G2 Tape Autoloader, and MSL2024, MSL4048, and MSL8096 Tape Libraries SAS tape drive firmware release notes Version U26W (AK378-96007, July 7, 2008)

Fixedacasewherethenumberoftimesacleaning cartridge was loaded was incorrectly
incremented.
FixedtwocommandsusedtocommunicatewiththeLibrary.
Installation instructions
To upgrade rmw
are from the RMI:
1. Download curr
ent rmware using HP Library & Tape Tools or from the HP support website:
h
ttp://www.h
p.com /support/storage.
2. Log into the RMI a s the administrator user.
3. In the Support: Firmware page,selectthetapedrive,browsetothelocationofthetapedrive
rmware le, and click Update.
4. Repeat step 3 for additional Ultrium 1760 SAS tape drives in the Library.
To upgrade
rmware from the 1/8 G2 Tape Autoloader or MSL2024 OCP using a USB ash drive:
1. Download c
urrent rmware using HP Library & Tape Tools or from the HP support website:
h
ttp://ww
w.hp.com/sup port/storage.Copythermware onto the USB ash drive.
2. Insert th
eUSBash drive into the USB port on the back of the Librar y.
3. From the Home screen, press Next until the screen displays Support.PressEnter to select.
4. Press Next until the screen displays Drive FW upgrade.PressEnter to select .
5. Enter the administrator password if prompted.
6. Press Ne
xt until the screen displays the lenameofthetapedrivermware le on the USB drive.
Press Enter to select the rmware le.
7. If the upgrade failed, press Enter to display the error code and message describing the cause of
the failure.
8. Repeat
step 7 if the Library has a second 1760 SAS tape drive.
9. When the upgrade is c omplete, remove the USB ash drive from the USB port.
To upgrade rmware from the MSL4048 or MSL8096 OCP using a USB ash drive:
1. Download current rmware using HP Library & Tape Tools or from the HP support website:
h
ttp://www.hp.com/support/storage.Copythermware onto the USB ash drive.
2. Insert the USB ash drive into the USB port on the back of the Library.
3. From the Support menu, select FW Upgrade > By USB.
4. Selectthetapedriveasthetargetfortheupgrade,andselectthelename of the rmware. Click
Upg
rade.
5. Re
peat step 4 for additional Ultrium 1760 SAS tape drives in the Library.
6. When the upgrade is c omplete, remove the USB ash drive from the USB port.
Determining current version
To nd the version of rmware installed on the Library, see the RMI Support: Firmware screen, the 1/8
G2 Tape Autoloader or MSL 2024 OCP Status/Information > Drive Information option, or the MSL4048
and MSL8096 OCP Info > Identity > Drives option.
Firmware V ersion
Released
Status
U24W Active
U26W
7/1/2008
Active
4