HP StoreEver MSL8048 and MSL8096 Tape Libraries Getting Started (AK382-96027, December 2012)

FC tape drive back panel overviews
LTO-4 and LTO-5 full-height drive
LTO-5 half-height drive
LTO-6 half-height drive
2. Fan1. Magazine access hole
4. FC port B3. FC port A
6. Tape drive power indicator5. Tape drive Ethernet port
(LTO-5 and LTO-6)
Power supply LEDs
AC power is connected.1. Blue
Fan failure. The fan is running too slow or is
defective.
2. Yellow
3. Green
The power supply is producing good power for the
library.
Using the operator control panel (OCP)
The OCP has a power button, four LEDs, five control
keys, and an LCD screen. With the OCP, you can
monitor, configure, and operate most library functions
from the library front panel.
See “Operator control panel menu (page 16) for the
OCP menu tree.
Control keys
The OCP displays a menu that lets you access
information and execute commands using the five
control keys: Up, Down, Left, Right, and OK.
LED indicators
The OCP has four LEDs that provide system status
information.
Ready Green, steady when power is on, blinking
with tape drive or library robotics activity.
Clean Amber when a tape drive cleaning operation
is recommended.
Attention Amber if the library has detected a
condition that user attention is necessary, but that the
device can still perform most operations.
Error Amber if an unrecoverable tape drive or
library error occurs. A corresponding error message
is displayed on the LCD screen. User intervention is
required; the device is not capable of performing some
operations.
Page 3